Gas Specifications - Buffalo CD963 Instruction Manual

Gas griddle
Table of Contents

Advertisement

Gas Conversion and Specifications
Commissioning
Before leaving the converted installation;
DO NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES.
1.
Check all gas connections for leakages.
2.
Check the following functions in accordance with the operating instructions specified in the
„Operation‟ section of this manual.
Light the Pilot Burner.
Light the Main Burner.
Check the „Low Fire‟ burner operation.
Check the „High Fire‟ Burner operation.
Ensure that all the controls operate correctly.
Ensure that the operating pressure remains correct.
3.
Ensure any adjustments done to components that have the adjustments / settings sealed (e.g. paint sealed) are
re-sealed.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the gas
supply and contact the supplier of this appliance.

Gas Specifications

Appliance Classification
Category:
Flue Type:
Main Burner Injector
Pilot Burner Injector
Operating Pressure
Supply Pressure
Gas Regulator Cap
Screw
Note: The burner operating pressure is to be measured at the gas control valve outlet test point with one
griddle burner operating at „High‟ setting. The operating pressure is ex-factory set, through the
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to the „Gas Conversion‟ section for details)
WARNING:
II2H3P & II2L3P
A1.
Natural Gas (G20)
CD963
CD964
43#
43#
2.28mm
2.28mm
0.45mm
15mbar
20mbar
15
Natural Gas(G25)
CD963
CD964
40#
40#
2.50mm
2.50mm
25mbar
Propane (G31)
CD963
CD964
53#
53#
1.51mm
1.51mm
0.25mm
25mbar
37&50mbar

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cd964