From System Setup, you may access CS Setup, User Setup, Time & Date, and Advanced Setup.

CS Setup

You may access ECP Address, CS Options/Operating Modes, Screen Security, Device Events,
Code Authority and Panel Configuration from the CS Setup screen.
From the "Home" screen, press the Setup and System Setup icon and perform the following:
ICON
1. From the System Setup screen, press
the CS Setup icon.
2. Enter your Authorized Code, if required.
3. Press the ECP Address icon.

ECP Address Selection

After enabling addresses in the control panel using an alpha-keypad, power-up each keypad one at a
time, and set its address to one of the addresses you enabled in the control panel. Otherwise, access
the Central Station screen then follow this procedure to change the address on the unit.
To change the address, perform the following:
ICON
1. Press the ECP Address icon.
1
2. Select the ECP address for this keypad
2
using the Up/Dn arrows.
3
3. The available ECP addresses are:
1-2, 5-6
1-2, 3-30
1-30
IMPORTANT: If multiple keypads are being used,
they must be set to addresses 1, 2, and X (where X
equals any address from 3 through 30). Only one
AUI type device may be assigned to an address
from 3 through 30 on commercial control panels.

System Setup

ACTION
ACTION
for residential controls
for commercial controls under
Rev. 10 supports 3 AUIs. See
Important Note below.
for commercial controls Rev. 10
and higher supports 6 AUIs.
If the top of the screen is displaying "ECP Error",
the ECP address in the keypad is not valid for
the panel that it is connected to. In this case,
change the ECP to the keypad default code of
"4140" to advance to the next screen.
Note: Default code "4140" is the Tuxedo Touch
default installer code before connecting to a
control panel. Once connected to a control
panel, use that panel's installer code.
When the keypad cannot communicate with the
alarm panel, the message "ECP Error" is
displayed, check the following:
Verify that the AUI type device is enabled in
the control panel, and that the ECP address in
the keypad matches the address enabled in the
control panel. Use a different address for each
device.
• If powering the keypad from a power supply,
make sure you have a common ground
installed (wiring between Power Supply "gnd"
and panel "Aux. power neg").
NOTE: When the ECP address is changed, and
Apply is selected, the keypad resets.
The keypad should not be assigned as a Master
Console. If the keypad is assigned as a Master
Console, partitions must be controlled from the
Partition screen or using the Console Emulation
Mode.
17