Initial Setup

Programming the Control Panel

The keypad is not fully operational unless its address in the control panel has been enabled (set as an
alpha console) AUI type device, and assigned to a partition (where applicable). For a list of alarm
systems that the keypad can interface with, refer to the "Compatibility Table" in Section 1 of this
document for the quantity of keypads that may be used and the required control panel software
revision level.
We recommend that you use either a standard alpha keypad or the keypad in Console Emulation Mode
when programming the control panel. When in the Console Mode, the keypad emulates an alpha
keypad and the programming of the panel is performed following the procedures provided in your
panel's Installation and Setup Guide.
Note: When programming your control panel, if you change the zone types for your emergency zones
you may disable the emergency buttons in the keypad. The emergency buttons in the keypad are active
for zone types 06 (Silent Panic Button), and 07 (Panic Button), 08 (Medical Button), and 09 (Fire
Button). Additionally, the Medical button is also compatible with a zone type 15 (24-Hour Medical) for
panels that contain this zone type.
On residential control panels (VISTA-20P or equivalent):
Up to four keypads may be used (addresses 1, 2, 5 and 6). Addresses 1 and 2 (in field *189) are enabled
by default. If the defaults have been changed, enable these addresses (in field *189) using an alpha-
keypad and the Data Field Programming procedures located in the panel Installation and Setup Guide.
On commercial control panels (VISTA-128BP, VISTA-128FBP, or equivalent):
Addresses 1-2, and 3-30 may be used for controls under Rev. 10 supporting 3 AUI's, see Important Note
below. Addresses 1-30 may be used for controls Rev. 10 and higher supporting 6 AUI's. These addresses
in the control panel are normally not defaulted for AUI type devices. To enable the addresses you are
using for keypads, use an alpha-keypad and follow the procedures for "Device Programming" in your
control panel "Programming Guide."
Important Note: If multiple keypads are being used, they must be set to addresses 1, 2, and X (where X
equals any address from 3 through 30). Only one AUI type device may be assigned to an address from 3
through 30 on commercial control panels.
The Keypad should not be assigned as a Master Console. If the keypad is assigned as a Master Console,
partitions must be controlled from the Partition screen or using the Console Emulation Mode.

Keypad Initialization

When initially powered, the screen displays the boot sequence and the "Set ECP Address" screen is
displayed.
If the system is incorporating only one keypad, leave the address set to 1 and press Apply. The boot-
up process continues until completion. If there are to be additional keypads in the system, after
enabling addresses in the control panel using an alpha-keypad, power-up each keypad one at a time,
and set its address to one of the addresses you enabled in the control panel.
Installer Note: The Tuxedo Touch Screen has been calibrated at the factory. Ignore the "CALIBRATE"
button that appears on the "Options" screen after initial ECP setup. If the screen should require
recalibration, the end user may do so via the "Keypad Test" screen. See the "Diagnostic Tests" section
for instructions.