Figure 3-10 Videoblox Configuration Tab - Honeywell ULTRAKEY LITE HJC5000 Installation And User Manual

Keyboard controller for videoblox and maxpro-net matrix systems
Table of Contents

Advertisement

Step 3A: Configure the Controller for a Serial Port Connection
Document 800-07422 Rev A
08/10
Note
By default, addresses 1– 5 in the VideoBloX NetCPU are set for serial
connection. Please change this in the NetCPU configuration if you want to
use addresses 1– 5 for Ethernet connection.
3.
Under VB Device Network Setting, enter the IP address and Port Number of the
VideoBloX system.
4.
Click Apply to save the configuration, Cancel to exit without saving, or Default to
restore all factory default values.
5.
Go to either Step 3A or 3B to configure the system for Serial or Ethernet connections
respectively.
Figure 3-10
VideoBloX Configuration Tab
Checking the Network Connection Using the Ping Function
After the IP address is entered and applied, press the Ping button.
A green Ping button indicates the device at this IP address has replied to the ping.
A red Ping button indicates the device at the IP address did not reply. Please check
that the IP address is correct and that there is a valid network path between the two IP
addresses.
1.
From the side menu, click Serial Port Configuration. See
UltraKey Lite Controller Installation and User Guide
Figure
3-11.
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents