CHASSIS INTERLINK INPUT AND OUTPUT MODULE
Rev 1.0
Table 8-2
DIP Switch
S3.1
A0
S3.2
A1
S3.3
A2
S3.4
A3
S3.5
A4
S3.6
A5
S3.7
A6
S3.8
A7
S4.1
A8
S4.2
A9
S4.3
A10
S4.4
P0
P1
S4.5
S4.6
Off = Normal / On = Switch 1 to 1
S4.7
Off = Normal / On = Test mode
S4.8
Not Used
•
Set the "End Address" SW3 (1-8) and SW4 (1-3) to match the address of the last input
card within the connected sub-chassis.
•
SW4/4-5 are reserved for future use in selecting protocols.
•
SW4 (6) is used for testing to switch inputs to the outputs, camera 1 to monitor 1,
camera 2 to monitor 2, camera 15 to monitor 15, etc.
•
Turn on SW4 (7) to enter test mode. In this mode, the module cycles various inputs to
outputs. This is useful for bench-top fault-finding and should not normally be used in
the field.
•
SW4 (8) is not used.
DIP Switch S3 and S4 Settings
Function
Interlink
End
Address
Protocol
48
900.0855