Table 8-2 Dip Switch S3 And S4 Settings - Honeywell VideoBloX User Manual

Matrix switcher chassis only
Hide thumbs Also See for VideoBloX:
Table of Contents

Advertisement

CHASSIS INTERLINK INPUT AND OUTPUT MODULE
Rev 1.0
Table 8-2
DIP Switch
S3.1
A0
S3.2
A1
S3.3
A2
S3.4
A3
S3.5
A4
S3.6
A5
S3.7
A6
S3.8
A7
S4.1
A8
S4.2
A9
S4.3
A10
S4.4
P0
P1
S4.5
S4.6
Off = Normal / On = Switch 1 to 1
S4.7
Off = Normal / On = Test mode
S4.8
Not Used
Set the "End Address" SW3 (1-8) and SW4 (1-3) to match the address of the last input
card within the connected sub-chassis.
SW4/4-5 are reserved for future use in selecting protocols.
SW4 (6) is used for testing to switch inputs to the outputs, camera 1 to monitor 1,
camera 2 to monitor 2, camera 15 to monitor 15, etc.
Turn on SW4 (7) to enter test mode. In this mode, the module cycles various inputs to
outputs. This is useful for bench-top fault-finding and should not normally be used in
the field.
SW4 (8) is not used.