Rack Mount System Chassis; Figure 1-2 Videoblox Matrix Switcher Rear View (Hvb4U Shown); Table 1-1 Videoblox Chassis - Honeywell VideoBloX User Manual

Matrix switcher chassis only
Hide thumbs Also See for VideoBloX:
Table of Contents

Advertisement

RACK MOUNT SYSTEM CHASSIS

Model No.
HVB2U
HVB4U
HVB8U
HVB12U
Rev 1.0
VideoBloX is housed in an industry standard 19" rack mountable chassis. Various chassis
heights are available to allow for different sized systems. The number of modules, which
may be fitted, is shown in the following table:
Table 1-1
VideoBloX Chassis
Chassis Height
2U
4U
8U
12U
VideoBloX modules are mounted from the front of the chassis. The modules are fitted
horizontally to allow for vertical system expansion. All modules (except the power supply
module) are position independent. Two thumb screws for removing modules from the
chassis are provided with each chassis. Refer to
VIDEOBLOX
CHASSIS.
Modules are "hot-swappable" and may be removed and reinserted with the power on. The
power supply module is fitted vertically beside the other modules. This module may not be
removed with the power switched on and is not position independent.
Figure 1-2
VideoBloX Matrix Switcher Rear View (HVB4U shown)
A separate termination card is inserted at the rear of the chassis. Termination cards for BNC
input/output, D type connectors, alarm connectors, etc. are available. Although modules
are position independent, it is necessary to match the module with the termination card.
All commonly used adjustments are accessible from the front. Adjustments / switch settings
which are made once at the time of installation, or when major reconfiguration is carried out,
are accessed by removing a module. Refer to
CHASSIS.
VideoBloX Chassis Only User Manual
Max Modules
Typical size
3
32 into 8
7
80 into 16 or 64 into 32
15
192 into 32 or 160 into 64
23
320 into 32 or 288 into 64
REMOVING A MODULE FROM A
REMOVING A MODULE FROM A VIDEOBLOX
3
900.0855
10/06

Advertisement

Table of Contents
loading