Ue Registration Procedure Of Csg Ues And Csg Or Hybrid Hnbs - Cisco ASR 5000 Series Administration Manual

3g home nodeb gateway
Hide thumbs Also See for ASR 5000 Series:
Table of Contents

Advertisement

HNB Gateway in UMTS Network
2. The UE then transmits a RRC Initial Direct Transfer message carrying the initial NAS message (e.g. Location
Updating Request message) with identity (IMSI or TMSI).
3. The HNB checks UE capabilities provided in step 1, if these indicate that CSG is not supported and if the
identity of the UE (provided during RRC Connection Establishment) is unknown at the HNB being accessed,
i.e. no Context id exists for the UE, the HNB initiates UE registration towards HNB-GW (step 6-8).
4. Before starting the UE Registration procedure, HNB optionally triggers the Identification procedure asking for
the UE IMSI, if such identity is not provided during the RRC Connection Establishment. If the HNB has a
context id for the UE, the UE registration procedure is not performed nor the Identification procedure.
5. The HNB may optionally perform access control based on IMSI and provided access control list.
6. The HNB attempts to register the UE on the HNB-GW by transmitting the UE-REGISTER-REQUEST. The
message contains at a minimum:
7. The HNB-GW checks UE capabilities and if these indicate that CSG is not supported the HNB-GW shall
perform access control for the particular UE attempting to utilize the specific HNB.
8. If the HNB-GW accepts the UE registration attempt it shall allocate a context-id for the UE and respond with a
UE-REGISTER-ACCEPT message, including the context-id, to the HNB. If the HNB-GW chooses to not
accept the incoming UE registration request then the HNB-GW shall respond with a UE-REGISTRATION-
REJECT message.
9. The HNB then sends a RUA (RANAP User Adaptation) CONNECT message containing the RANAP Initial UE
message to HNB-GW.
10. The reception of the RUA CONNECT message at the HNB-GW triggers the setup of SCCP connection by the
HNB-GW towards the CN. HNB-GW forwards the Initial UE Message to CN.
11. The CN response with a SCCP Connection Confirm message to HNB-GW.
12. The UE then continue with the NAS procedure (e.g. Location Updating procedure) towards the CN, via HNB
and the HNB-GW.

UE Registration Procedure of CSG UEs and CSG or Hybrid HNBs

This procedure is applicable for CSG UEs and CSG or Hybrid HNBs.
The following figure and the text that follows describe the message flow of UE registration procedure for CSG UEs and
CSG or Hybrid HNBs..
OL-22991-01
UE Identity: IMSI of the (U)SIM associated with the UE and the indication about UE capabilities
provided in step 1.
I
:
MPORTANT
The UE IMSI provided in the UE-REGISTER message is unauthenticated.
Cisco ASR 5000 Series 3G Home NodeB Gateway Administration Guide ▄
How HNB-GW Works ▀

Advertisement