3.4 MODES OF OPERATION, CONTINUED
3.4.3 Device (DVR) Operation Mode, Continued
To exit device (DVR) mode of operation, press another mode key (Camera, Monitor, or
Sequence).

3.4.4 Sequence Operation Mode

In this mode of operation, use the numeric keypad to select the active sequence, and
then press Enter. Alt + joystick left and Alt + joystick right simulates "Previous" and
"Next". Alt + joystick up starts the currently selected sequence. Alt + joystick down
function stops the sequence.

3.4.5 Alarm Acceptance

Alarms may be set up (by the main CCTV control system) in such a way that the
operator is alerted by an alarm tone. To accept an alarm, the operator must press the
ALM ACK (Alarm Acknowledge) key.
3.4.6 LCD Function Keys F1-F16
After logging into the system, the operator can scroll through functions F1 through F16
on the LCD using the left and right arrow keys. Function Keys F1 to F16 are configured
in the VideoBloX System Configuration under the Users tab or Keyboards tab
(configurable keys). They can be user-specific or keyboard-specific. If the keys are not
defined under the Users tab, then the Keyboard definitions are the default. If they are
defined under the Users tab then that user's login overrides the keyboard-defined
functions.
Press the soft key that corresponds to the function key to invoke the definitions defined
for that key.
Rev. 1.01
12
900.0799
20-Jun-06