Parameters
<string 22> - Enter the maintenance association name used here. This name can be up to 22
characters long.
ma_index - Specifies the maintenance association index used.
<uint 1-4294967295> - Enter the maintenance association index value used here. This value
must be between 1 and 4294967295.
md - Specify the maintenance domain name.
<string 22> - Specify the maintenance domain name. The maximum length is 22 characters.
md_index - Specifies the maintenance domain index used.
<uint 1-4294967295> - Enter the maintenance domain index value used here. This value
must be between 1 and 4294967295.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command. (EI Mode Only
Command)
Example
To create a maintenance association called "op1" and assign it to the maintenance domain
"op_domain":
DGS-3620-28SC:admin#create cfm ma op1 md op_domain
Command: create cfm ma op1 md op_domain
Success.
DGS-3620-28SC:admin#
15-4

config cfm ma

Description
This command is used to configure the parameters of a maintenance association. The MEP list
specified for an MA can be located in different devices. MEPs must be created on the ports of
these devices explicitly. An MEP will transmit a CCM packet periodically across the MA. The
receiving MEP will verify these received CCM packets from the other MEPs against this MEP list
for the configuration integrity check.
Format
config cfm ma [<string 22> | ma_index <uint 1-4294967295>] md [<string 22> | md_index
<uint 1-4294967295>] {vlanid <vlanid 1-4094> | mip [none | auto | explicit | defer] | sender_id
[none | chassis | manage | chassis_manage | defer] | ccm_interval [3.3ms | 10ms | 100ms |
1sec | 10sec | 1min | 10min] | mepid_list [add | delete] <mepid_list 1-8191> | mode [software
| hardware]}(1)
Parameters
<string 22> - Specify the maintenance association name. The maximum length is 22 characters.
ma_index - Specifies the maintenance association index used.
<uint 1-4294967295> - Enter the maintenance association index value used here. This value
must be between 1 and 4294967295.