Installing the Chassis Ground Connection

Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance
with local electrical safety standards.
OL-5786-03
For NEBS-compliant grounding, use size 6 AWG (13 mm
in the accessory kit.
Note
NEBS-compliant grounding is not supported on the Cisco 2801 router.
For NEC-compliant grounding, use size 14 AWG (2 mm
user-supplied ring terminal with an inner diameter of 1/4 in. (5–7 mm).
For EN/IEC 60950-compliant grounding, use size 18 AWG (1 mm
appropriate user-supplied ring terminal.
Installing the Chassis Ground Connection
2
) copper wire and the ground lug provided
2
) or larger copper wire and an appropriate
Chassis Installation Procedures for Cisco 2800 Series Routers
2
) or larger copper wire and an
13