Table 5 - Advanced Configuration Parameters - Honeywell SmartLine SLN700 User Manual

Level transmitter non-contact radar hart option
Hide thumbs Also See for SmartLine SLN700:
Table of Contents

Advertisement

Key:
Plain = Read only
Bold = Configurable
Calibrate Date
Dust or Agitation
MultiWave
First Echo Option
Envelope Level
Echo Threshold
Burnout Direction
Low Dk Option
Empty Span
False echo distance
Set False Echo Distance
Revision 1

Table 5 - Advanced Configuration parameters

Bold underline = Method
Echo Settings
Enter the date of calibration.
Normal
Set the degree of Dust or Agitation.
Mild
Medium
Strong
No
Select the MultiWave algorithm to get the correct echo.
Yes
Normal
Select the weight of the first echo.
Small
Big
Bigger
Biggest
dB
Set the level of the envelope.
dB
Set the threshold size of the effective echo.
No Change
Select the burnout current.
21.5mA
3.6mA
No
Select the Dielectric constant
Yes
M
M
Entered distance value will be the range to capture false
echo envelop. Echo peaks present in false echo will not
be picked as level by the device. Live peaks different than
the false echo observed during the operation of the device
will be accounted for level qualification when product
surface comes in the false echo range.
Yes
Use this method to set the False Echo Distance.
No
SLN700 Series HART
Bold italic = Table or graph
Option User's Manual
Page 17