Innova 2000 Cardiovascular Imaging
System
Pre–Installation Manual
pim
do not duplicate
E
Copyright
2002, 2003, 2004 and 2005 by General Electric Co.

Advertisement

Table of Contents
loading

Summary of Contents for GE Innova 2000

  • Page 1 Technical Publications 2337741–100 Revision 5 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual do not duplicate Copyright 2002, 2003, 2004 and 2005 by General Electric Co.
  • Page 2 Geräte bedienen oder sich selbst und andere Personen deren Bestrahlung aussetzen können. Vor Inbetriebnahme dieses Apparats sollte sich das qualifizierte und befugte Bedienungspersonal mit den geltenden Kriterien für den ge- fahrlosen Strahleneinsatz durch sorgfältiges Studium des Hefts Nr. 26 der Internationalen Kommission für Strahlenschutz (ICRP) vertraut...
  • Page 3: Table Of Contents

    ........Description of the Innova 2000 Imaging System .
  • Page 4 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Audible noise ............
  • Page 5: Rev

    ..... . . JOB CARD PIST044–001 – INNOVA 2000 SYSTEM INTERCONNECT ...
  • Page 6 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 PROCESS ORDER SELECT .........
  • Page 7 Falls ein fremder Kundendienst eine andere Sprache benötigt, ist es Aufgabe des Kunden für eine entsprechende Übersetzung zu sorgen. Wird diese Warnung nicht beachtet, so kann es zu Verletzungen des Kundendiensttechnikers, des Bedieners oder des Patienten durch Stromschläge, mechanische oder sonstige Gefahren kommen.
  • Page 8 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ATENÇAO NÃO TENTE REPARAR O EQUIPAMENTO SEM TER CONSULTADO E COMPREENDIDO ESTE MANUAL DE ASSISTÊNCIA TÉCNICA Este Manual de Assistência Técnica só se encontra disponível em Inglês.
  • Page 9: Chapter 1 - Introduction

    A complete Innova LC positioner comprises only three parts. D Innova 2000 positioner/titan cabinet, D Innova 2000 positioner including an X–ray tube housing with a SIEMENS collimator and a 22 cm Revolution Digital Detector. D Multiaxis control (smart handle+/or Smart Box).
  • Page 10: Description Of The X-Ray Generator

    D MPPU5 – Microgrid H.V. tank mounted on the Maxiray150 X – Ray tube housing. Description of the X–Ray head The Innova 2000 System uses a MAXIRAY 150 tube housing including an X–Ray tube, a SIEMENS collimator, VMP micro grid HV tank, oil/water exchanger, contour filter, etc.
  • Page 11: Description Of The Innova 2000 Imaging System

    2337741–100 Description of the Innova 2000 Imaging System An Innova 2000 System is managed and controlled by a System including: D Atlas cabinet (inside which are located the RTAC, the DL, the modem, the HUB, the KVM, the 4 KVA PDU), D Innova Console with a plasma screen mounted on a wall support or pedestal, D 22 cm Revolution Digital Detector mounted on Innova LC positioner.
  • Page 12: Tv Monitors

    GEMNet option Refer to: D Document FP10105, GEMNet System (Ethernet) Pre–Installation Manual. D Document 2266396–100 (GEMS) or 2002377–003 (GE Marquette), GEMNet Image Vault Pre–Installation Guide. 2-10 Injectors ILLUMINA injectors (Remote or Pedestal) are offered. Other injectors (Remote or Pedestal) S.O.I. required.
  • Page 13: Innova Lc Product Identification

    GE Medical Systems REV 5 pim 2337741–100 INNOVA LC PRODUCT IDENTIFICATION Innova LC positioner The Innova LC positioner includes a positioner cabinet, a positioner and TSUI. Table 1 – INNOVA 2000 BASIC PRODUCT Part LOCATION DESIGNATION Number of Name Plate...
  • Page 14 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 1 – POSTIT CABINET...
  • Page 15 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 2 – INNOVA LC BASIC PRODUCT Innova LC Positioner Innova LC positioner including: D L–arm (Item 1), D Pivot (Item 2), D C–arc (Item 3), D motorized elevator (Item 4) for the Revolution Digital Detector, D X–ray tube (Item 5),...
  • Page 16 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 3 – OMEGA PATIENT TABLE BASIC PRODUCT MULTIAXIS CONTROL BOX MULTIAXIS CONTROL HANDLE (OR SMART BOX) (OR SMART HANDLE +) TABLE SIDE CONTROL (OR TSSC+)
  • Page 17 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 4 – OMEGA PATIENT TABLE OMEGA PATIENT TABLE Illustration 5 – X–RAY TUBE CHILLER & DIGITAL DETECTOR CHILLER X–Ray tube CHILLER Digital Detector CHILLER...
  • Page 18 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 6 – ACAB CABINET...
  • Page 19 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 7 – INNOVA USER AREA 17” Hi–Brite Image Monitor Color flat panel (15”), keyboard and mouse Remote control Keypad Innova console...
  • Page 20: Product Options

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Product Options Illustration 8 – PRODUCT OPTIONS TV MONITOR 17" or 21" VCR 220 V OR 110 V INDICATOR UNIT...
  • Page 21: Responsibilities Of The Purchaser/Customer

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 RESPONSIBILITIES OF THE PURCHASER/CUSTOMER To ensure that the installation of an Innova Cardio System meets the purchaser or customer expectations, it is important to determine who will take responsibility for the various items during the system installation process.
  • Page 22 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 23: Pre-Installation Process

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 PRE-INSTALLATION PROCESS Complete the checklists in Chapters 5, 6, and 7 of this manual. They represent an important part of the pre–installation process. The checklists summarize the required preparations and allow to verify the proper completion of the pre–installation procedures.
  • Page 24 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 25: Chapter 2 - System Compatibility

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 CHAPTER 2 – SYSTEM COMPATIBILITY BASIC INNOVA LC SYSTEM COMPATIBILITY Table 3 – SYSTEM COMPATIBILITY CROSS–REFERENCE TABLE – INNOVA LC POSITIONER/TABLE SUB-SYSTEM PRE–INSTALLA- TION PRODUCT NAME...
  • Page 26 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Table 6 – SYSTEM COMPATIBILITY CROSS REFERENCE TABLE – X–RAY HEAD/TABLE SUB–SYSTEM PRE–INSTALLA- TION PRODUCT NAME MODEL NUMBER NOTES DOCUMENT NUMBER Maxiray 150 X–Ray tube 2149520–4...
  • Page 27 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Table 8 – SYSTEM COMPATIBILITY CROSS–REFERENCE TABLE – TV MONITOR SUPPORT & TV SUSPENSION/TABLE SUB–SYSTEM PRE–INSTALLATION PRODUCT NAME MODEL NUMBER CATALOG NUMBER DOCUMENT NUMBER PRECABLED 3 MONITOR...
  • Page 28: Optional Innova Lc System Components

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 OPTIONAL INNOVA LC SYSTEM COMPONENTS Table 10 – SYSTEM COMPATIBILITIES CROSS–REFERENCE TABLE – OMEGA TABLE SUB–SYSTEM PRE–INSTALLA- TION CATALOG PRODUCT NAME MODEL NUMBER DOCUMENT NUMBER NUMBER SMART HANDLE 2237456–3...
  • Page 29: Chapter 3 - Physical Requirements Of Room

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 CHAPTER 3 – PHYSICAL REQUIREMENTS OF ROOM...
  • Page 30 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 31: Environmental Requirements/Limitations

    GE Medical Systems REV 5 pim 2337741–100 ENVIRONMENTAL REQUIREMENTS/LIMITATIONS Room Climate CAUTION Avoid extremes in temperatures. Table 13 – INNOVA 2000 SYSTEM ROOM CLIMATE REQUIREMENTS (BY COMPONENT) – RELATIVE HUMIDITY AND TEMPERATURE RELATIVE HUMIDITY TEMPERATURE (NON–CONDENSING) PRODUCT OR PRODUCT OR IN–USE...
  • Page 32 Refer to Table 14. To obtain altitude and atmospheric pressure requirements for components not specified in Table 14, refer to the appropriate component Pre–Installation Manual listed in Chapter 2. Table 14 – INNOVA 2000 SYSTEM ROOM CLIMATE REQUIREMENTS – ALTITUDE AND ATMOSPHERIC PRESSURE...
  • Page 33: Equipment Heat Output (Dissipation)

    Refer to Table 15. To obtain heat output information for components not specified inTable 15, refer to the appropriate component Pre–Installation Manual listed in Chapter 2. Table 15 – INNOVA 2000 SYSTEM HEAT OUTPUTS (BY COMPONENT) HEAT OUTPUT (BTU/HR) HEAT OUTPUT (WATTS)
  • Page 34: Iec601-1-2 Electromagnetic Standard Compliance & Documentation

    Table 16 – Electromagnetic Emission The Innova 2000 system is suitable for use in the specified electromagnetic environment. The purchaser or user of the Innova 2000 system should assure that it is used in an electromagnetic environment as described below:...
  • Page 35: Electromagnetic Immunity

    Table 17 – Electromagnetic Immunity The Innova 2000 system is suitable for use in the specified electromagnetic environment. The purchaser or user of the Innova 2000 system should assure that it is used in an electromagnetic environment as described below: Immunity Test IEC 60601–1–2...
  • Page 36 Table 18 – Electromagnetic Immunity IEC 60601–1–2 The Innova 2000 system is suitable for use in the specified electromagnetic environment. The purchaser or user of the Innova 2000 system should assure that it is used in an electromagnetic environment as described below: Immunity Test IEC 60601–1–2...
  • Page 37: Limitations Management

    (in order to avoid images interferences risks). Innova 2000 system USE LIMITATION : 1-3-5 The use of accessories, transducers, and cables other than those specified may result in degraded ELECTROMAGNETIC COMPATIBILITY of the Innova 2000 system...
  • Page 38: Installations Requirements & Environment Control

    D Low frequency magnetic field: In case of an Innova 2000 system, the Gantry(digital detector) shall be apart 1meter from the generator cabinet, and 1meter apart from the analog (CRT) monitors. These distances specifications shall minimize the low frequency...
  • Page 39 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 D Static magnetic field limits: In order to avoid interference on the , static field limits from Innova 2000 system the surrounding environment are specified. Static field is specified less than <1 Gauss in Examination room, and in the Control Area.
  • Page 40: Radiation Protection

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Radiation Protection Because x–ray equipment produces radiation, special precautions may be needed or special site modifications may be required. The General Electric Company does not make recommendations regarding radiation protection.
  • Page 41: Preference Cabinet Location

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Preference Cabinet location Illustration 10 – PREFERRED SYSTEM CABINET LOCATION IN ALL CASES ACAB Cabinet...
  • Page 42 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 43: Structural Requirements

    Room Size Refer to Table 20 for recommended and minimum Innova LC system room dimensions. The Innova 2000 system room dimensions reflect the specifications determined by General Electric Medical Systems Installation Services group. Table 20 – INNOVA LC SYSTEM RECOMMENDED AND MINIMUM ROOM SIZE DIMENSIONS...
  • Page 44 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 The floor slabs on which the equipment is to be installed must have a CAUTION levelness of 1 mm (0.04 in) per meter (40 in) . Baseplate and table basement must be at the same level.
  • Page 45 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 12 – THROUGH–BOLT SUPPLIED (PAN TYPE FLOOR CONSTRUCTION) FOR EXAMPLE 1/4 inch (6 mm) to 1/2 inch (13 mm) grout pad Floor Baseplate thru bolt M20–500–400 Flat washer É...
  • Page 46 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 14 – HOLE LOCATIONS IN CONCRETE FLOOR OMEGA IV No cable entry (7.677) INNOVA LC POSITIONER in this area diameter 225 mm Isocenter or 9 inches É...
  • Page 47 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 15 – WATER CONDUIT LOCATION ISOCENTER THRU–FLOOR FITTING ABOVE GRADE 4.5” WATER LINES [114mm] 1” [25mm] I.D. CONDUITS LCA BASEPLATE FOR WATER LINES (FOUR REQ’D) TABLE SIDE 5.0”...
  • Page 48 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 16 – CABLE CURVATURE ISOCENTER THRU–FLOOR FITTING THRU–FLOOR WATER LINES LCA BASEPLATE TABLE SIDE Mini radius = 150 mm (6 inches) (FLOOR) (FLOOR) Electrical cables coming...
  • Page 49: Ceiling

    REV 5 pim 2337741–100 Ceiling Aluminum rails support the In–Room TV Monitor bridge used in Innova 2000 system X–ray rooms. Reference For additional details on ceiling requirements for stationary rails, refer to: D Direction 46–019639, Advantx (VHLA) XT Stationary Rails Installation and Adjustment.
  • Page 50 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 17 – Recommended locations for 3 TV monitor suspension and rad shield 2500 (98.42) 660.4 660.4 660.4 660.4 660.4 660.4 660.4 (26) (26) (26) (26)
  • Page 51 2337741–100 Radiation Shield A counterbalanced radiation shield can be supplied as an option with an Innova 2000 System. The radiation shield longitudinal axis is not always the same as the OMEGA Patient table longitudinal axis. A counterbalanced radiation shield can be supplied with a pair of rails. To mount the rails, you will have to install 3 m steel beams before delivery of the Innova 2000 System.
  • Page 52: Walls

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Walls General requirement A normal way to mount heavy cabinets such as ACAB Cabinet, POSTIT Cabinet and X–Ray Generator Cabinet is to securely fasten them to the wall to prevent them from tipping.
  • Page 53: Insite

    CAUTION System. InSite requires an Internet Address connecting it to the Innova 2000. This address must be available before installing the system. A request form has been defined. For more information, please refer to Chapter 8 or contact your GEMS OLC representative.
  • Page 54 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 55: Chapter 4 - Physical Characteristics

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 CHAPTER 4 – PHYSICAL CHARACTERISTICS DIMENSION DRAWINGS Refer to this section for the dimensional drawings of the components of the Innova LC Positioner and Omega Tables sub-systems. These components include: D Innova LC Positioner.
  • Page 56 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 TABLE OF ILLUSTRATIONS TITLE ILLUSTRATION PAGE DL KEYPAD AND FLAT PANEL (DIMENSIONS) Illustration 32 DL IMAGE MONITOR (DIMENSIONS) Illustration 33 VCR VIDEO STATION (OPTIONAL) Illustration 34...
  • Page 57 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 19 – INNOVA LC POSITIONER DIMENSIONS All dimensions are in mm (inches) Center of gravity (25.2) R 1.552 (24) (25.2)
  • Page 58: Illustration 19 B

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 19 b – INNOVA LC POSITIONER DIMENSIONS All dimensions are in mm (inches) (3.07)
  • Page 59 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 20 – OMEGA IV COMPACT PATIENT TABLE DIMENSIONS All dimensions are in mm (inches) É É 1080 3 (42.52 0.12) É É É É 140 3...
  • Page 60 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 21 – OMEGA V LONG PATIENT TABLE DIMENSIONS 1.080 (42.52 .12) (30.71 0.12) LCA ISOCENTER TABLE PIVOT SIDE VIEW 1007 10 TOP VIEW FRONT VIEW...
  • Page 61 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 22 – POSTIT CABINET DIMENSIONS All dimensions are in mm (inches) (9.06) Gravity Center (34.85) (18.11)
  • Page 62 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 23 – ACAB CABINET DIMENSIONS All dimensions are in mm (inches) (12.4) 1500 WARNING: (59) A free space up from the floor is required in front of the cabinet to open the door.
  • Page 63 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 24 – X–RAY CHILLER DIMENSIONS The maximum elevation difference between X–Ray Tube Housing and CAUTION Chiller is around 3 meters (10 ft). Exact dimensions of the chiller depends on the model type.
  • Page 64: Illustration

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 25 – DETECTOR CHILLER DIMENSIONS All dimensions are in mm (inches) (13.82) 141 REF (5.55) (0.79) (4) 6.35 Dia. (0.25) (1.57) (7.99) (11.14) (12.24) (0.79)
  • Page 65 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 26 – DETECTOR CHILLER – CONFIGURATION & ORIENTATION CLEAR AIR ZONE BULKHEAD AIR FLOW & BULKHEAD LOCATION...
  • Page 66 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 27 – INNOVA LC POSITIONER AND OMEGA IV COMPACT PATIENT TABLE RELATIVE POSITIONS (SIDE VIEW) All dimensions are in mm (inches) (54.92) SIDE VIEW...
  • Page 67 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 28 – INNOVA LC POSITIONER AND OMEGA IV COMPACT PATIENT TABLE RELATIVE POSITIONS (TOP VIEW) All dimensions are in mm (inches) 1395 (54.92) 4470 (14 ft 8 in)
  • Page 68 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 29 – INNOVA LC POSITIONER AND OMEGA IV COMPACT PATIENT TABLE RELATIVE POSITIONS (FRONT VIEW) FRONT VIEW...
  • Page 69 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 30 – INNOVA LC POSITIONER AND OMEGA V LONG PATIENT TABLE RELATIVE POSITIONS (SIDE VIEW) All dimensions are in mm (inches) 1395 (54.92) SIDE VIEW...
  • Page 70 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 31 – INNOVA LC POSITIONER AND OMEGA V LONG PATIENT TABLE RELATIVE POSITIONS (TOP VIEW) All dimensions are in mm (inches) 1278 (50.31) 160 mini (6.30)
  • Page 71 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 32 – DL KEYPAD AND FLAT PANEL (DIMENSIONS) All dimensions are in mm (inches)
  • Page 72 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 33 – DL IMAGE MONITOR (DIMENSIONS) All dimensions are in mm (inches) 183.5 (7.22) 259.9 (10.23) 325.2 (12.80) 323.6 (12.74) 394.6 (15.53) 21 (0.8) 243 (9.57)
  • Page 73 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 34 – VCR VIDEO STATION (OPTIONAL) All dimensions are in mm (inches) (14.57) (10.63) VCR 220 V OR 110 V INDICATOR UNIT...
  • Page 74: Swept Volume Curves

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 35 – VCR MOUNTING HOLES LOCATION All dimensions are in mm (inches) 16.5 (14.57) (0.65) BOTTOM VIEW (9.33) (10.63) 16.5 (10.98) (0.65) Note: Unscrew the four “feet” on the bottom. Use these four holes to fix the VCR. The mounting holes accommodate M3 x 10 mm screws.
  • Page 75 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 36 – INNOVA LC POSITIONER INTERFERENCE REGIONS All dimensions are in mm (inches) SIDE VIEW FRONT VIEW (61.1) (24) TOP VIEW...
  • Page 76 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 37 – OMEGA IV COMPACT PATIENT TABLE INTERFERENCE REGIONS All dimensions are in mm (inches) É É É É É É 1007 10 É É É É...
  • Page 77 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 38 – OMEGA V LONG PATIENT TABLE INTERFERENCE REGIONS 1.080 (42.52 .12) TABLE ROTATION (30.71 0.12) 180_ 180_ LCA ISOCENTER TABLE PIVOT 180_ 180_ SIDE VIEW...
  • Page 78 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 79: Mounting Requirements

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 MOUNTING REQUIREMENTS Floor Loading and Recommended Mounting Methods See Table 22. To obtain floor loading and recommended mounting methods for components not specified in Table 22, refer to the appropriate component Pre-Installation Manual listed in Chapter 2.
  • Page 80: Positioner And Table Floor Mounting

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 LOAD LOAD DIMENSIONS WEIGHT/ WEIGHT/ PRODUCT OR PRODUCT OR MOUNTING MOUNTING BEARING BEARING WEIGHT WEIGHT OCCUPIED OCCUPIED COMPONENT COMPONENT METHOD METHOD AREA AREA KG (LBS) KG (LBS)
  • Page 81 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 39 – INNOVA LC POSITIONER FLOOR MOUNTING METHODS ABOVE GRADE THRU M20 GRADE 5, BOLT M20 THRU-BOLT & WASHER GROUT 0.25 in. - 0.5 in. (6 mm - 13 mm)
  • Page 82 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ABOVE GRADE THROUGH BOLTS M20 GRADE 5, PAN TYPE FLOOR CONSTRUCTION THRU-BOLT & WASHER GROUT 0.25 in. - 0.5 in. (6 mm - 13 mm) FITTING MUST EXTEND THICK 0.25 in.
  • Page 83 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 40 – CABLE CONDUIT FOR ON–GRADE FLOOR ANCHOR KIT...
  • Page 84 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 41 – INNER BASE PLATE FOR ABOVE GRADE FLOOR ANCHOR KIT...
  • Page 85 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 42 – INNOVA LC/OMEGA V LONG TABLE SYSTEM FLOOR MOUNTING TEMPLATE (PREFERRED) NOTE 1 USE HOLE PATTERN "A" FOR LCA+, LCV+ & LC+/INNOVA/OMEGA V 2 HOLE PATTERN "B" CAN BE USED AS AN ALTERNATIVE TO HOLE PATTERN "A"...
  • Page 86 REV 5 pim 2337741–100 Illustration 43 – INNOVA LC/OMEGA IV COMPACT OR OMEGA V LONG TABLE SYSTEM FLOOR MOUNTING TEMPLATE On Innova 2000, use only hole patern A or B See Illustration 13 É É É É É É É É...
  • Page 87: Innova Lc Positioner And Omega Table Floor Preparation Kits (Gems Supplied)

    Select Kit 2285054 All GE supplied vascular system floor preparation are contained in catalog. There are some additional gantry/table mounting kits based on the on each mounting method: through bolts or floor anchors. D Base plate assembly (mandatory) 2285048 – Refer to Table 23 D Assembly and separation (Select kit) 2285050 –...
  • Page 88 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Table 23 – 2285048 – Base Plate Assembly ITEM NAME PART # DESCRIPTION QUAN. NOTES Baseplate 2285059 12 HoleFloor Baseplate 1 pc Lift Plate 2290939 Lifting Straps...
  • Page 89: Illustration 41

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 2285646 – Through bolts without insert ITEM NAME PART # DESCRIPTION QUAN. NOTES Through Bolt; M20 - 500-400 Through Bolt mounting Bolt, Hex 2296892 16 pc...
  • Page 90: Illustration 41

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 2285052 – Above grade, Floor anchor with insert ITEM NAME PART # DESCRIPTION QUAN. NOTES Floor Anchor Bolt; 5/8-10 x 6 in. dril Above Grade ling...
  • Page 91: Illustration 43

    1: Old Kit B5079 KS is replaced by 2285048, and B5079 KT is split into 2285056 and 2186109. 2: The kit 2285632 Floor plate / Baseplate assembly is needed when the floor plate is installed. This part isn’t GE part. It’s ordered locally; used currently in some European countries, and would be used worldwide.
  • Page 92: Ceiling Loading And Recommended Mounting Methods

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Ceiling Loading and Recommended Mounting Methods See Table 26. To obtain ceiling loading and recommended mounting methods for components not specified in Table 26, refer to the appropriate component Pre-Installation Manual listed in Chapter 2.
  • Page 93: Chapter 5 - Room Layouts

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 CHAPTER 5 – ROOM LAYOUTS...
  • Page 94 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 95: Room Layout Considerations

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ROOM LAYOUT CONSIDERATIONS Radiation Protection Because X–Ray equipment produces radiation, you may need to take special precautions or make special site modifications. The General Electric Company does not make recommendations regarding radiation protection.
  • Page 96 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 97: Room Layout Drawings

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ROOM LAYOUT DRAWINGS See Illustration 45, Illustration 46, Illustration 47, Illustration 48 and Illustration 49, for recommended room layouts for an Innova LC system. ROOM SPEAKER If the Advantx console tone cannot be heard from the exam room, a remote loud–speaker must be...
  • Page 98 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 45 – RECOMMENDED ROOM LAYOUT FOR INNOVA 2000 SYSTEM 6000 (19 ft 8 in) + 0.25 (+ 10)
  • Page 99: Omega Iv Compact Patient Table

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ROOM DIMENSIONS L X W CEILING HEIGHT RECOMMENDED: 32 ft. 0 in. x 20 ft. 0 in. 10 ft. 0 in. (9.75 m x 6.00 m) (3.05 m)
  • Page 100 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 46 – RECOMMENDED ROOM LAYOUT FOR INNOVA 2000 SYSTEM CAUTION TV Monitor suspension shown on this illustration is not finalized location yet.
  • Page 101 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ROOM DIMENSIONS L X W CEILING HEIGHT RECOMMENDED: 32 ft. 0 in. x 20 ft. 0 in. 10 ft. 0 in. (9.75 m x 6.00 m) (3.05 m)
  • Page 102 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 47 – RECOMMENDED ROOM LAYOUT FOR INNOVA 2000 SYSTEM 6000 (19 ft 8 in) + 0.25 (+ 10)
  • Page 103 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ROOM DIMENSIONS L X W CEILING HEIGHT RECOMMENDED: 32 ft. 0 in. x 20 ft. 0 in. 10 ft. 0 in. (9.75 m x 6.00 m) (3.05 m)
  • Page 104 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 48 – RECOMMENDED ROOM LAYOUT FOR INNOVA 2000 SYSTEM 6000 (19 ft 8 in) + 0.25 (+ 10)
  • Page 105 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ROOM DIMENSIONS L X W CEILING HEIGHT RECOMMENDED: 32 ft. 0 in. x 20 ft. 0 in. 10 ft. 0 in. (9.75 m x 6.00 m) (3.05 m)
  • Page 106: Illustration

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 49 – RECOMMENDED ROOM LIGHTING FOR INNOVA 2000 SYSTEM 6000 (19 ft 8 in) + 0.25 (+ 10) ZONE 1 ZONE 2 ZONE 3...
  • Page 107 Zone 1 – Intensive lighting needed by operator. Manually cut. Zone 2 – Variable lighting without specular reflection on Display and monitor screens. Indirect lighting but preferably from ceiling automatically cut by the Innova 2000 System. In Control room Zone 3 – Variable lighting without artifact on Display and monitor screens.
  • Page 108 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 50 – INNOVA 2000 SYSTEM WITH DIGITAL MOBILE 9800 Refer to Illustration 45 for the legend.
  • Page 109 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 51 – INNOVA 2000 SYSTEM WITH DIGITAL MOBILE 9800 Refer to Illustration 46 for the legend.
  • Page 110 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 111 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 CHAPTER 6 – ELECTRICAL CONNECTIONS...
  • Page 112 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 113 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 CABLE CHANNELING Conduit Conduit has some important restrictions when used with modularized X-ray systems. The primary consideration is that most of the cables used are preterminated, which greatly simplifies interconnection, but makes cable-pulling difficult because of the added dimensions of the connectors.
  • Page 114 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 POWER DISTRIBUTION Illustration 52 – AC INTERCONNECT...
  • Page 115 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ROOM DISTRIBUTION Innova LC provides a room distribution from Positioner cabinet as follows: a. X–ray–on–line (low voltage limited to 24 Vac). Acting during X–Ray exposures. b. X–ray–on–line (yellow, low voltage limited to 24 Vac).
  • Page 116 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 53 – GROUNDING INTERCONNECT...
  • Page 117 D Document 2337743–100, INNOVA 2000 MIS Charts. General Guidelines Innova 2000 introduce a new system interconnect with a star distribution for all cables from the technical area. The cables are shipped on spools to create cable groups. Cable group 1 for Exam room and cable group 2 for control room.
  • Page 118 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 INJECTORS Remote Injector (rack mount) A power cord is supplied with the injector. If the voltage is 110 Vac, the cord should be connected inside the bulkhead positioner cabinet, but it is highly recommended to connect it to a wall outlet fed by the main disconnect room device.
  • Page 119 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 RECOMMENDED POWER DISTRIBUTION SYSTEM The drawing hereafter is a guide to illustrate all functions included inside CAUTION the main disconnect room device. It should be compliant with the specific country rules.
  • Page 120 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Typical PDB WITH AUXILIARY CONTACT...
  • Page 121 Refer to Chapter 6 – Section 3 – Room distribution. EMERGENCY An Innova 2000 System has to be powered by a second circuit coming from an emergency power generator. In this case, if the power is cut for about 20 seconds, the system reboot is long and requires about 5 minutes.
  • Page 122 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 123 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 PHYSICAL RUNS 11-1 Synoptic Illustration 54 – PHYSICAL RUN - SYNOPTIC MINI / MAXI INTERCONNECTION LENGTH DISTANCES EXPRESSED IN TRENCH LENGTH DISTANCES EXPRESSED IN TOTAL LENGTH...
  • Page 124 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 11-2 System Core Matrix All lengths of cable are: CAUTION – in useable meter when you look at group level, or – in meters (connector to connector) when you look at the cable level.
  • Page 125 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 56 – CABLE GROUP 2 – FROM TECHNICAL AREA TO CONTROL ROOM...
  • Page 126 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 57 – CABLE GROUP 3 – FROM TECHNICAL AREA TO TECHNICAL AREA This group enables to split the cabinets in 2 areas: one for VAMP cabinet and one for POSTIT and ACAB cabinets.
  • Page 127 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 58 – CABLE GROUP 4 WITH STANDARD SUSPENSION Suspension are always pre–cabled with 24 meter cables of connector to connector Monitor options includes their 24 meters length for cabling...
  • Page 128 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 59 – CABLE GROUP 4 WITH LCD SUSPENSION...
  • Page 129 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 11-3 System Core Detail Table 28 – PHYSICAL RUN – SYSTEM CORE DETAIL Cable Bigger dimen- Voltage Cable Voltage diam- Connector Plug Min. sions rating carried...
  • Page 130 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Cable Bigger dimen- Voltage Cable Voltage diam- Connector Plug Min. sions rating number Assembly Style carried eter type size conduit flush (mm) (mm) floor Group n 2 (From ACAB / POSTIT to Control Booth) (SubD 15 pts –...
  • Page 131 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Cable Bigger dimen- Voltage Cable Voltage diam- Connector Plug Min. sions rating number Assembly Style carried eter type size conduit flush (mm) (mm) floor Group n 3 (From ACAB / POSTIT to VAMP)
  • Page 132 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Cable Bigger dimen- Voltage Cable Voltage diam- Connector Plug Min. sions rating number Assembly Style carried eter type size conduit flush (mm) (mm) floor Group n 4–1 (From ACAB / POSTIT to Monitors–Standard suspension)
  • Page 133 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Cable Bigger dimen- Voltage Cable Voltage diam- Connector Plug Min. sions rating number Assembly Style carried eter type size conduit flush (mm) (mm) floor 27993 2385196...
  • Page 134 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 135 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 JOB CARD PIST044–007 – System facility power Time: 0 h 15 min – Personnel: 1 field engineer 1 of 8 SUPPLIES D None. TOOLS D None.
  • Page 136 The room ground point is located: D in the distribution panel (PDB) for Innova 2000 system and for any other medical devices powered in the examination room (refer to Illustration 2).
  • Page 137 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 3 of 8 JOB CARD PIST044–007 – System facility power Illustration 1 – Room ground point description High Intensity = GROUND WIRE Light = POWER (HOT & NEUTRAL)
  • Page 138 JOB CARD PIST044–007 – System facility power PROCEDURE The facility shall provide to the GE installation specialist a written statement that the grounding and power supply meets General Electric’s specifications including the 2 ohms to earth before the system installation begins.
  • Page 139 Signature below confirms that all customer/contractor supplied equipment (se definition in NEC article 100) and wiring conductors required have been installed will provide power as specified in GE Medical System preinstalltion drawings an meets requirements set forth in GE Medical System direction 2290880–10 Innova 2000 Pre–Installation Kit Installation Procedures.
  • Page 140: Illustration 2

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 6 of 8 JOB CARD PIST044–007 – System facility power Illustration 2 – Ground connection at distribution panel DISTRIBUTION PANEL INCOMING OUTGOING GROUNDING BLOCK APPROVED FOR...
  • Page 141: Illustration 3

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 7 of 8 JOB CARD PIST044–007 – System facility power Illustration 3 – Wire impedance test NEMA MAIN PANEL ADAPTOR MODEL 120/240 PLUG INPUT CIRCUIT CABLE...
  • Page 142: Illustration 4

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 8 of 8 JOB CARD PIST044–007 – System facility power Illustration 4 – Ground rod impedance test ECOS 2300 NOTE: TO ENSURE PROPER MEASURE MENT OF THE GROUND ROD, THE GROUNDING CONDUCTOR FROM A FACILITY MUST BE REMOVED.
  • Page 143 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 JOB CARD PIST044–001 – Innova 2000 System Interconnect Time: 9 h 00 min – Personnel: 2 field engineers = 18 h 00 of workload 1 of 10 SUPPLIES D None.
  • Page 144: Illustration 1

    GE Medical Systems REV 5 pim 2337741–100 2 of 10 JOB CARD PIST044–001 – Innova 2000 System Interconnect PROCEDURE Unpack the spools The cables sets are delivered on a pallet, lengths were defined during ordering process, with the cable select process. The pallet includes group 1...
  • Page 145 REV 5 pim 2337741–100 3 of 10 JOB CARD PIST044–001 – Innova 2000 System Interconnect D Use the two wooden forms as a slope to run the spool on the pallet , The cable set will be pulled from the bottom side of the spool.
  • Page 146 2337741–100 4 of 10 JOB CARD PIST044–001 – Innova 2000 System Interconnect D Put in place the two forms to build side support with anchor D Put the axis in the spool and raise the spool to avoid contact with the pallet.
  • Page 147 REV 5 pim 2337741–100 5 of 10 JOB CARD PIST044–001 – Innova 2000 System Interconnect D Cables are included in a long plastic bag to limit the cables crossed. This plastic bag can be kept on site in the gullet, depending on local regulations.
  • Page 148 REV 5 pim 2337741–100 6 of 10 JOB CARD PIST044–001 – Innova 2000 System Interconnect Run the cable Set Group 1 1. Unroll the cable set from the spool and lie it down between gantry and technical area (power cables are not linked to the cable set).
  • Page 149 REV 5 pim 2337741–100 7 of 10 JOB CARD PIST044–001 – Innova 2000 System Interconnect Run the cable Set Group 4 Group 4 links the 3 Monitor suspension to the Technical area. This cable set of 24 meters is delivered with the suspension.
  • Page 150 GE Medical Systems REV 5 pim 2337741–100 8 of 10 JOB CARD PIST044–001 – Innova 2000 System Interconnect Run the cables for Extra monitors The extra monitors are delivered with their respective composites cables: D These two options are independent.
  • Page 151 GE Medical Systems REV 5 pim 2337741–100 9 of 10 JOB CARD PIST044–001 – Innova 2000 System Interconnect D 6 cables between POSTIT and ACAB cabinets. D 2 cables between ACAB cabinet and conditioner. D 1 cable between MPPU and ACAB cabinets.
  • Page 152 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 10 of 10 JOB CARD PIST044–001 – Innova 2000 System Interconnect Blank page.
  • Page 153 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 CHAPTER 7 – ADDITIONAL PLANNING AIDS...
  • Page 154 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 155 PRODUCT SHIPPING INFORMATION Refer to Table 29. To obtain shipping information for components not specified in Table 29, refer to the appropriate component Pre-Installation Manual listed in Chapter 2. Table 29 – INNOVA 2000 SYSTEM PACKING DIMENSIONS WEIGHT PRODUCT OR...
  • Page 156 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 DIMENSIONS WEIGHT WEIGHT PRODUCT OR PRODUCT OR METHOD OF METHOD OF INCHES (METERS) POUNDS POUNDS COMPONENT COMPONENT SHIPMENT SHIPMENT (KILOGRAMS) (KILOGRAMS) Height Width Depth TV monitor susp.
  • Page 157: Illustration 2

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 DETAIL OF INNOVA SHIPPING INFORMATION Illustration 2 – INNOVA LC POSITIONER GANTRY ON SHIPPING DOLLY Height mini 1950 (77) 2190 (10) (86.22) (34) (11.5) ] 300 mm...
  • Page 158 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 3 – INNOVA LC POSITIONER AIR SHIPMENT (114) (90.5) (54.5) DIMENSIONS IN CM (INCHES) NOT TO SCALE...
  • Page 159: Illustration 4

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 4 – INNOVA LC POSITIONER CABINET ON SHIPPING DOLLY APPROX. 209 (82) 74 (29) 132 (52) DIMENSIONS IN CM (INCHES) NOT TO SCALE This cabinet is shipped strapped to two dollies. The cabinet requires a door opening of about 82 inches (208 cm) high and 29 inches (74 cm) wide when attached to the dollies.
  • Page 160: Illustration 5

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 5 – OMEGA SHIPMENT Base assembly Table top assembly (76.75) (137) (32) (32.33) (33) DIMENSIONS IN CM (INCHES) NOT TO SCALE...
  • Page 161: Illustration 6

    Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 6 – OMEGA USING POSITIONER DOLLIES Rail retainer Dolly channel Side plate Dolly screw (two required) Lifting bracket (Red) Dolly nose Base plate plate attaching...
  • Page 162 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 7 – OTHER ELEMENTS PACKAGE Note: All OEM parts are shipped inside there original boxes group as needed on pallets. (16.2)
  • Page 163 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 TOOLS AND TEST EQUIPMENT Refer to Table 30. To obtain a list of tools and test equipment for components not specified in Table 30, refer to the appropriate component Pre-Installation Manual listed in Chapter 2.
  • Page 164 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 PRODUCT OR TOOL OR RECEIVED USED FOR SOURCE COMPONENT TEST EQUIPMENT (DATE) Same as for Innova LC (Service Engineer’s Tool Case) Fill in any additional tools or test equipment as required...
  • Page 165 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 ROUTE SURVEY Step One — Sketch Start preparing Route Survey by sketching a floor plan of the hospital or clinic which will receive the equipment. Include all areas on the delivery route from outside the building to destination. See sample sketch below.
  • Page 166 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Table 31 – ROUTE SURVEY TABLE ROUTE SURVEY Ref. Area: loading dock, doorway, hallway, Limitations: loading capacity, height, width, depth turn, elevator, obstruction, etc. flooring material, radius, etc.
  • Page 167 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 PROCESS ORDER SELECT Generality Several components like cables, stationary rails, etc. are length selectable. This selection should reflect the particularities encountered by an Installation Specialist on Site.
  • Page 168 Refer to Table 33. This table can help anybody to select a system cable and component set. Now an electronic tool defined for Innova 2000 system is available for all GEMSE’s and GEMSA’s Installation Specialist and sent to GEMSE’s Vascular OCP where all the information is processed.
  • Page 169 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Illustration 9 – XT STATIONARY RAIL LENGTHS 3,404 All dimensions are in millimeters 3,505 3,607 203 51 3,708 305 51 3,810 3,912 4,013 Particularity 4,115 4,216...
  • Page 170 EUROPE/ASIA PROCESS US PROCESS Innova 2000 SEND THIS DOCUMENT 5 WEEKS BEFORE Conduit length Meters UPDATE THE FDO IN CSS DATABASE SHIPMENT TO VASCULAR OCP BUC Cable Group Select FAX 33 1 30 70 40 10 OR INCLUDE WITH THE SELECTED PARTS IN E–MAIL @MED VASC SELECT CBL...
  • Page 171 System PIM received by site planner ISERV known by FE / RSE / CII Service and Diagnostic tools available in country Installation team trained on the INNOVA system, EHS & GE policy GE team and/or Subcontractor agreement on SAD Specific day identified for delivery Equipment &...
  • Page 172 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Period Great Poor O L P – – – Exam room well prepared: Ceiling: Rails in place & plastic covers available Ceiling light agreed by radiologist Wall , Floor: Raceways, conduits in place Floor: Anchor holes done for gantry (Qty 16) &...
  • Page 173 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 CHAPTER 8 – IP ADDRESSING PROCESS To obtain an IP address, contact the following for your pole: GEMSAM: Contact: OnLine Center–Americas Network Products and Services (NP&S) Telephone: 1–800–321–7937...
  • Page 174 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.
  • Page 175 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 REVISION HISTORY DATE REASON FOR CHANGE PAGES June 12, 2002 Initial release, VCP version created from 2276550–100 October 30, 2002 Manual updated for Heroic 2 October 28, 2003...
  • Page 176 Innova 2000 Cardiovascular Imaging System Pre–Installation Manual GE Medical Systems REV 5 pim 2337741–100 Blank page.

Table of Contents