13. Before making a service call
- Trip information and remedies
13.1 Trip causes/warnings and remedies
When a problem arises, diagnose it in accordance with the following table.
If it is found that replacement of parts is required or the problem cannot be solved by any remedy described in the
table, contact your Toshiba dealer.
[Trip information]
Error code
Failure code
0001
0002
0003
0004
0005
*
0008
0009
*
*
You can select a trip ON/OFF by parameters.
(Continued overleaf)
Problem
Overcurrent during
• The acceleration time is too short.
acceleration
• The V/F setting is improper.
• A restart signal is imput to the rotating
motor after a momentary stop, etc.
• A special motor (e.g. motor with a small
impedance) is used.
Overcurrent during
• The deceleration time is too short.
deceleration
Overcurrent during
• The load fluctuates abruptly.
constant speed
• The load is in an abnormal condition.
operation
Overcurrent (An
• The insulation of the output main circuit or
overcurrent on the
motor is defective.
load side at start-up)
• The motor has too small impedance.
Arm overcurrent at
• A main circuit elements is defective.
start-up
Input phase failure
• A phase failure occured in the input line of
the main circuit.
• The capacitor in the main circuit lacks
capacitance.
Output phase failure
• A phase failure occurred in the output line
of the main circuit.
Possible causes
• Increase the acceleration time .
• Check the V/F parameter.
• Use (auto-restart) and
• Adjust the carrier frequency .
• Set the carrier frequency control mode
• Increase the deceleration time .
• Set the carrier frequency control mode
• Reduce the load fluctuation.
• Check the load (operated machine).
• Set the carrier frequency control mode
• Check the cables and wires for defective
• Make a service call.
• Check the main circuit input line for phase
• Enable (input phase failure
• Check the capacitor in the main circuit for
• Check the main circuit output line, motor,
• Enable (Output phase failure
M-1
E6581595
Remedies
(ride-through control).
selection parameter f316 to 1 (carrier
frequency decreased automatically).
selection parameter f316 to 1 (carrier
frequency decreased automatically).
selection parameter f316 to 1 (carrier
frequency decreased automatically).
insulation.
failure.
detection).
exhaustion.
etc. for phase failure.
detection).
13