Toshiba VFNC3-2001P Instruction Manual page 219

Industrial inverter
Table of Contents

Advertisement

efesotomasyon.com -Toshiba inverter,drive,servo,plc
• Communication parameters
Communication
Title
Function
No.
0800
Baud rate

0801
Parity

0802
Inverter number

0803
Communication

time-out time
0804
Communication

time-out action
0808
Communication

time-out detection
condition
0829
Selection of

communication
protocol
0870
Block write data 1

0871
Block write data 2

0875
Block read data 1

0876
Block read data 2

0877
Block read data 3

0878
Block read data 4

0879
Block read data 5

0880
Free notes

Note: Chapter 5, 6 or 7 indicated in the reference column refers to item "E6581595" in the instruction manual.
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
-
-
3: 9600bps
4: 19200bps
5: 38400bps
-
-
0: NON (No parity)
1: EVEN (Even parity)
2: ODD (Odd parity)
-
1/1
0-247
s
0.1/0.1
0.0: Disabled,
0.1-100.0
-
-
0: Alarm only
1: Trip (Coast stop)
2: Trip (Slowdown stop)
-
-
0: Always
1: When  or 
communications is selected
2: 1 + during operation
-
-
0: Toshiba inverter protocol
1: Modbus RTU protocol
-
-
0: No selection
1: Command information
2: -
3: Frequency setting
-
-
4: Output data on the terminal board
5: Analog output for communications
-
-
0: No selection
1: Status information
2: Output frequency
-
-
3: Output current
4: Output voltage
-
-
5: Alarm information
6: PID feedback value
-
-
7: Input terminal board monitor
8: Output terminal board monitor
-
-
9: V1 terminal block monitor
-
1/1
0-65535
K-15
E6581595
Default
User
Reference
setting
setting
4
6.19
1
0
0.0
0
1
0
0
0
0
0
0
0
0
0
6.20
11