6.17.2 Calibration of analog output
: Analog output signal selection
: Inclination characteristic of analog output
: Analog output bias
• Function
*
Analog output signal selection
6
Note 1: With 0 to 20 mA dc (4 to 20 mA dc) output, or 0 to 10 V dc output, set to or .
Note 2: , , and are parameters for manufacturer settings. Do not change this parameter.
Example of setting
Output signal from the FM terminal can be switched between 0 to 1 mA dc output, 0 to 20 mA dc
output, and 0 to 10 V dc output with the setting. The standard setting is 0 to 1 mA dc output.
Optional frequency meter: When using QS60T, set = (meter option (0 to 1 mA) output).
Title
Function
Inclination characteristic of analog
output
Analog output bias
=1, =1, =0(%)
(mA)
20
0
0
Internal calculated value
=1, =0, =100(%)
(mA)
20
: Large gain
0
0
Internal calculated value
The analog output inclination can be adjusted using the parameter .
Adjustment range
0: Meter option (0 to 1 mA) output
1: Current (0 to 20 mA) output
2: Voltage (0 to 10 V) output
0: Negative inclination (downward slope)
1: Positive inclination (upward slope)
-1.0 - +100.0%
=1, =1, =20(%)
(mA)
20
4
f692
100%
=1, =0, =100(%)
(mA)
20
f692
4
100%
F-56
Default setting
0
100%
Internal calculated value
: Small gain
0
100%
Internal calculated value
E6581595
0
1
0