6.5.3
 : External logic input - UP response time
 : External logic input - UP frequency steps
 : External logic input - DOWN response time
 : External logic input - DOWN frequency steps
 : Initial value of UP/DOWN frequency
 : Change of the initial value of UP/DOWN frequency
• Function
■ Parameter settings
6




 Initial value of UP/DOWN frequency

■ Input terminal settings
Assign the following functions to the input terminal, you can change (up/down) or clear the output frequency
by using the terminal's ON/OFF.
88
90
92
Note 1: Each of the following numbers (89, 91, 93) are reverse signals.
Setting of frequency with the input from an external
contact
These parameters are used to set an output frequency by means of a signal from an external device.
Title
Function
External logic input - UP response
time
External logic input - UP frequency
steps
External logic input - DOWN response
time
External logic input - DOWN frequency
steps
Change of the initial value of
UP/DOWN frequency
This function is valid when the parameter (frequency setting mode selection) =  is set.
Input terminal function
Frequency UP signal input from
external logic input
Frequency DOWN signal input from
external logic input
External logic input up/down
frequency clear
Adjustment range
0.0 - 10.0 (S)
0.0 -  (Hz)
0.0 - 10.0 (S)
0.0 -  (Hz)
 -  (Hz)
0: Not changed
1: Setting of  changed
when power is turned off
ON
Frequency setting increase
Frequency setting decrease
OFF
ON: External contact up/down
frequency Clear settings
F-14
E6581595
Default setting
0.1
0.1
0.1
0.1
0.0
1
OFF
Clear
Clear
 settings