Free unit display
scale
*
The converts the following parameter settings:
• Free unit Frequency monitor display
6.18.4 Changing the steps in which the value increment
: Free step 1 (1-step rotation of setting dial)
• Function
It is possible to change the step width changed at panel frequency setting.
This function is useful when only running with frequencies of intervals of 1 Hz, 5 Hz, and 10 Hz units.
Note 1: The settings of these parameters have no effect when the free unit selection ( ) is enabled.
Note 2: Set to other than 0. When increasing the frequency by rotating the setting dial and if
(max. frequency) is exceeded by rotating 1 step more, be careful as the alarm displays before
this happens and the frequency cannot be increased beyond this point.
Similarly, when rating the settings dial to lower the frequency, if the rotating 1 step more lowers it
below (lower limit frequency), the alarm displays before this happens and the frequency
cannot be lowered beyond this point.
Title
Free step (1-step rotation of setting
dial)
Operation example
= 0.00 (disabled)
By rotating the setting dial 1 step, the panel frequency command value changes only 0.1 Hz.
When = 10.00 (Hz) is set
Rotating the setting dial 1 step changes the panel frequency command value in 10.00 Hz increments, from
0.00 up to 60.00 (Hz).
Function
0.00: Disabled (display of frequency)
0.01-200.0
Frequency-related parameters
Function
F-61
Adjustment range
Operation frequency command, Operation
frequency, PID feedback, Frequency command
value After correction, Operation frequency
command at trip
, , , , ∼ ,
, , , , ,
, , , , ,
, , , ,
∼ , , ,
Adjustment range
0.00: Disabled
0.01- (Hz)
E6581595
Default setting
0.00
6
Default setting
0.00