System Status; Magnetic Wand - Honeywell RAEGuard 3 User Manual

Fixed gas detector
Table of Contents

Advertisement

6.2 System status

RAEGuard 3 provides users with simple and clear system status indications,
which is convenient for users to judge and know the danger level of the site and
whether the instrument is running normally.
System
Red LED
status
Low alarm
High alarm
Flashing/1s
Low alarm latch
High alarm latch
Flashing/1s
Overrange
Flashing/1s
STEL alarm
TWA alarm
Inhibit
Warning
Fault
Normal
Nore: Fault, inhibit and warning current can be set to 1 mA or 2 mA or 3 mA. Overrange current can be set
to 21 mA or 22 mA or 23 mA. But It is not recommended to modify these default values.
For more information on fault codes and warning codes, please refer to Section
11.

6.3 Magnetic Wand

Users can operate RAEGuard 3 via Magnetic Switch.
There are 3-switch ▲, √, ▼ on the transmitter, which can be recognized by the Magnetic
Switch operating icon on the LCD display.
Left, Mid, Right Click (>1s)
Left, Mid, Right Hold (>3s)
Left, Mid, Right Hold (>20s)
Green LED
Solid
Flashing/1s
Flashing/1s
Solid
Flashing/1s
Flashing/1s
Flashing/1s
Solid
Flashing/1s
Solid
Flashing/1s
Flashing/1s
Flashing/1s
Flashing/1s
Flashing/1s
RAEGuard 3 User Manual
Yellow
LCD Display
LED
+Concentration
+Concentration
+Concentration
+Concentration
+Concentration
+ Concentration
Solid
+warning code
Flashing/2s
+fault code
Flashing/1s
25
Analog current
output
4-20(±0.1) mA
4-20(±0.1) mA
4-20(±0.1) mA
4-20(±0.1) mA
22(±0.5) mA
4-20(±0.1) mA
4-20(±0.1) mA
2(±0.5) mA
3(±0.5) mA
1(±0.5) mA
4-20(±0.1) mA