please refer to the below diagrams.
If you need to add sunshade/deluge protection cover, use the two
4.
M8*25 screws that comes with the sunshade/deluge protection, to fix it
on the top of two holes. (See section 14 "Sunshade/Deluge Protection
Drawing")
Vertical
Mounted
Use Mounting Plate Kit to mount:
Select the suitable installation position and bury vertical or horizontal
1.
pipe/structure (Diameter/cross section: 20-80mm) prior to mounting
RAEGuard 3.
See the following procedure to fix the optional Mounting Plate Kit on the
2.
pipe/structure;
At diagonal positions secure the two M8*6 screws to the four holes in
3.
the back of enclosure of the RAEGuard 3 transmitter;
Refer to "Step 1", align the transmitter to the 2 holes on the mounting
4.
plate;
As per "Step 2", rotate the transmitter clockwise to perpendicular to the
5.
ground;
Tighten the four M8*25 screws through the four holes.
6.
Step 1
Note: For further details and information, see Chapter 14.
When installing, the detector's sensor must be perpendicular to the ground!
Horizontal
Mounted
Step 2
15
RAEGuard 3 User Manual
Wall Mounted
Mounted
with
Sunshade/Deluge
protection
Step 3