Functions 16. Option Slots

16.8 EUROMAP67 Board

EUROMAP67 is a standardized interface for communications between Western-
manufactured injection molding machines (IMM) and robots.
List of accessories
2194667
2194667
2165789
2194882
Wire the emergency stop switch wiring connector (CN3).
The connector signal placement is described below.
List of connectors used
CN1
CN2
CN3 (accessory)
CN4
190
Parts Code
EUROMAP67 Cable1
EUROMAP67 Cable2
CN1
EUROMAP67Emergency Connector Plug
EUROMAP67Emergency Connector
Shell
Reference: 11.3 Pin Assignments
Reference: 16.8.11 Emergency stop connecter Pin Assignments
Connecter No.
Manufacturer
JAE
3M
3M
Tyco
Parts
CN2
CN4
DD-50PF-N
10126-3000PE, 10326-52K0-008
10136-3000PE, 10336-52K0-008
T1319320125-000 / T2020252201-000 /
T2020252101-000
Note
Emergency Stop cable
(CN2)
Connection cable
Robot Controller(CN1)
- IMM(CN4)
For emergency stop switch
wiring
Soldering plug (CN3)
For emergency stop switch
wiring