Chassis Weight; Installation Guidelines - Cisco 5000 Series Hardware Installation Manual

Platform and switch
Hide thumbs Also See for 5000 Series:
Table of Contents

Advertisement

Chapter 3
Installing the Cisco Nexus 5500 Platform or 5000 Series Switch

Chassis Weight

When lifting the system, follow these guidelines:

Installation Guidelines

When installing the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch, follow these
guidelines:
Note
Caution
OL-15902-01
S e n d c o m m e n t s t o n 5 k d o c s @ c i s c o . c o m
Disconnect all power and external cables before lifting the system.
Have two people to lift the system. The Cisco Nexus 5548P switch weighs 35 lb (15.88 kg).
The Cisco Nexus 5020 switch weighs 50 lb (22.680 kg and the Cisco Nexus 5010 switch weighs 35
lb (15.876 kg)
.
Ensure that your footing is solid and the weight of the system is evenly distributed between your
feet.
Lift the system slowly, keeping your back straight. Lift with your legs, not with your back. Bend at
the knees, not at the waist.
Plan your site configuration and prepare the site before installing the chassis.
Planning and Maintenance Records,"
Record the information listed in
install and configure the switch.
Ensure that there is adequate space around the switch to allow for servicing the switch and for
adequate airflow
(Appendix B, "Technical Specifications,"
Ensure that the air-conditioning meets the heat dissipation requirements listed in
"Technical Specifications."
Ensure that the cabinet or rack meets the requirements listed in
Installation."
Jumper power cords are available for use in a cabinet. See the
page
C-12.
Ensure that the chassis is adequately grounded. If the switch is not mounted in a grounded rack, we
recommend connecting both the system ground on the chassis and the power supply ground to an
earth ground.
Ensure that the site power meets the power requirements listed in
Specifications."
If available, you can use an uninterruptible power supply (UPS) to protect against
power failures.
Avoid UPS types that use ferroresonant technology. These UPS types can become unstable
with systems such as the Cisco Nexus 5548P switch or the Cisco Nexus 5000 Series switch,
which can have substantial current draw fluctuations because of fluctuating data traffic
patterns.
Ensure that circuits are sized according to local and national codes. For North America, the power
supply requires a 15-A or 20-A circuit.
lists the recommended site planning tasks.
Appendix D, "Site Planning and Maintenance Records,"
Cisco Nexus 5000 Series Hardware Installation Guide
Preparing for Installation
Appendix D, "Site
lists airflow requirements).
Appendix B,
Appendix A, "Cabinet and Rack
"Jumper Power Cord" section on
Appendix B, "Technical
as you
3-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nexus 5500Nexus 5000 series

Table of Contents