To connect an alarm device to the alarm port, follow this procedure:
The alarm connector is a 3-wire connector that plugs into a receptacle in the rear of the chassis. The connector is
Note
provided in the accessory kit that ships with the universal gateway.
Insert the three-pin alarm port connector (included in the accessory kit) into the alarm port terminal block.
Step 1
Step 2
Strip a minimum 1/4 in. (0.625 cm) off the wire insulation to connect the stranded wires to the alarm connector. The
maximum insulation strip length is 0.31 in. (0.78 cm).
Use stranded Number 12 or 14 AWG copper wires to connect an alarm device to the alarm port connector.
Note
Secure the wires to the alarm connector with the screws on the connector.
Step 3
The maximum tightening torque on the screws is 7 in.-lb (0.79 N-m).
Caution
Connecting Alarm Device to Cisco AS5350
To alarm device
Connecting Alarm Device to Cisco AS5400
#1
Cable ties
Step 4
Attach two cable ties to the chassis and connect the wires to the cable ties.
Step 5
Attach the alarm wires to the alarm device.
#1
Cable ties
#2
Alarm port
connector
#3
#2
Alarm port
connector
#3