ENGLISH
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. The Variable Speed Pump must be installed by
WARNING
a licensed or certified electrician or a qualified service professional in accordance with the National Electrical
Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which
could result in death or serious injury to users, installers, or others due to electrical shock, and may also cause
damage to property.
Always disconnect power to the pump at the circuit breaker before servicing the pump. Failure to do so
could result in death or serious injury to service people, pool users, or others due to electric shock
and/or property damage.
Read all servicing instructions before working on the pump.

3.5 Wiring Overview and Installation

All electrical wiring MUST be in conformance with all
applicable local codes, regulations, and the National Electric
Code® (NEC®). Contact a qualified electrician if you cannot
verify that the circuit is protected by a GFCI. The unit must
be connected only to a supply circuit that is protected by a
ground-fault circuit-interrupter (GFCI). Such a GFCI should
be provided by the installer and should be tested on a
routine basis. To test the GFCI, push the test button. The
GFCI should interrupt power. Push the reset button. Power
should be restored. The GFCI is defective if the GFCI fails
to operate in this way. If the GFCI interrupts power to the
pump without the test button being pushed, a ground current
is flowing, indicating the possibility of an electric shock. Stop
using this pump. Disconnect the pump and ask a qualified
professional to correct the problem before using.
The pump accepts 230V, 50, or 60Hz single phase input
power. The terminal block connections are capable of
handling up to 12AWG solid or stranded wire. There are
also fast-on type quick connectors, however, check the local
electrical codes for the desired connection method. The
connections must be permanently made to the grounding
terminal (see Figure 4) in the field wiring compartment
according to the local electrical code.
The drive will operate on 2-phase Line-Line-Ground
electrical systems as well as Line-Neutral-Ground systems.
This pump must be permanently connected by a circuit
breaker as specified in the local electrical code.
WARNING:RISK OF ELECTRIC SHOCK.
1. Be sure all electrical breakers and switches are turned off
before wiring motor. Always wait five (5) minutes after
disconnecting the power from the pump before opening
or servicing the drive.
2. Choose a wire size for the pump in accordance with the
current National Electrical Code and all applicable local
codes and ordinances. When in doubt use a heavier
gauge (larger diameter) wire. Be sure the wiring voltage
is within the operating range.
Installation & Operation Manual
3. Be sure all electrical connections are clean and tight.
4. Cut wires to the appropriate length so they do not overlap
or touch when connected to the terminal board.
5. Permanently ground the motor using the ground screw
located on the inside rear of the controller interface (see
Figure 4). Use the correct wire size and type specified by
the current National Electrical Code. Be sure the ground
wire is connected to an electrical service ground.
6. Bond the motor to all metal parts of the pool structure and
to all electrical equipment, metal conduit, and metal
pipping within 5 feet (1.5 M) of the inside walls of the
swimming pool, spa or hot tub in accordance with the
current National Electrical Code. UL requires use of a solid
copper bonding conductor not smaller than 8 AWG. See
Figure 4.
Note: For Canada, a 6 AWG or larger solid copper bonding
conductor is required.
7. The pump should be permanently connected to either a
circuit breaker, 2-pole timer or 2-pole relay. If AC power is
supplied by a GFCI circuit breaker, use a dedicated circuit
breaker that has no other electrical loads.
8. Connect the pump permanently to a circuit. Make sure no
other lights or appliances are on the same circuit.
1/2"NPT threaded
Grounding
Terminal
The field wiring compartment has a 1/2" NPT
threaded conduit port for the liquid-tight fitting. The
bonding lug should be used to bond the motor
frame to the equipment pad.
AC Power
Bonding
Connections
Lug
Figure 4