Honeywell Lyric LCP300-L User Reference Manual page 25

Hide thumbs Also See for Lyric LCP300-L:
Table of Contents

Advertisement

Including Door Locks
For security, Z-Wave door locks are encrypted, and enroll at low power
transmission range (approximately 6 feet). This requires Including the lock before
its installation in a door.
Assemble the lock, connect necessary cables and install batteries according to the device's
instructions. Be sure the door lock's orientation/handedness is correct.
Z-Wave door locks vary. Refer to the device's instructions to ensure that it is Included
properly and to program a user code.
After Inclusion, install the lock within recommended Z-Wave range (see
more information).
NOTES: • Program the 4-digit user code into the Gateway. When programming user codes
into the Gateway, determine if the user will have access to the Z-Wave lock. If so,
the user code will be transferred to the lock.
• If using a lock with Smart Scenes, automatic locking/re-locking features should be
disabled.
• Due to Low Power Inclusion Mode of secure devices, Include the Z-Wave Lock
first, if not using an Inclusion Tool/Remote Control. The lock should be installed
before including other devices.
• During operation, the system will display "JAMMED" and will revert to "Unlocked"
status if a jammed lock is detected.
• When performing a command directly from a thermostat or water shutoff valve, a
change of status message may not appear at the Controller.
Including Thermostats
Install and test the thermostat before Including it in your system. Refer to the device's
instructions for more information about installation.
Honeywell is not responsible for property damages due to improper setting of
thermostat modes.
NOTES: • Some thermostats do not update temperature status automatically.
• When using Z-Wave thermostat control on the Gateway, the thermostat's
scheduling feature should not be used.
• When the HOLD button on the Gateway's thermostat control screen is
highlighted, Z-Wave scenes driven by Smart Scenes will not affect thermostat
operation. Additionally, if your system is connected to remote services, the
remote 7-day schedules will also not affect thermostat operation.
• For threshold monitoring to be configurable on the remote services and Z-Wave
thermostat screens, the respective zones will first need to be assigned with a
response type in zone programming. Threshold monitoring is not available on all
thermostats.
• Both Zones for each respective thermostat must be programmed (for example,
Zone 180 & 181 for thermostat #1, Zone 182 & 183 for thermostat #2 and Zone 184 &
185 for thermostat #3).
• When temperature is represented in Celsius, Gateway matches the temperature
increment of the particular thermostat for Heat, Emergency Heat and Cool set
points. Increments can be one degree or half degree, depending on the
thermostat.
• If Celsius scale is used in the thermostat, the Gateway must also be set to Celsius
scale.
• If the Energy Saving mode is set, the
Heat/Cooling Setpoint Temperatures that are programmed at the thermostat.
• An additional "Energy Saving" function in the thermostat is used to set/unset the
Energy Saving mode.
IMPORTANT
IMPORTANT
Gateway
displays Energy Saving
25