Terminal Box for Double-Cabling - Frame Size 530G / 530L

Total shield connection via cable clamp of strain relief in the screwed
cable connection
Connect the temperature sensor SNM.150.DK for motor protection on
the drive device
The temperature sensor KTY84-130 can be only used for external tem‐
peratue measuring
Fig.8-16:
Connection overview on the terminal box
The motor connection for the stator frame sizes 530G and 530L must be done
via two power cables.
The following connection diagram shows a possible connection.
When planning the double cabling, please note the applicable in‐
stallation regulations at the installation site of the machine.