Chapter 1 Maintenance
[?]
Event ID129
The following message appears on Windows Event Log
Event source : megasas2
Event ID
Type
Description : Reset to device, \Device\RaidPortX, was issued.
→
Retry by OS has succeeded. It is not the problem in operating the system.
(As for x, arbitrary numbers enter.)
[?]
DISK LED flashes
DISK LED flashes frequently even while the Hard disk drive is not accessed.
→
When Patrol Read is running, the DISK LED flashes even if the Hard disk drive is not being
accessed. If SATA Hard disk drive is used, the DISK LED may stay on.
[?]
When N8403-034 is used, the names of the Fibre Channel controllers may appear with different names
on Device Manager
→
When N8403-034 is used in Windows Server 2012 or Windows Server 2008 R2 or Windows
Server 2008, a different controller name may be displayed per controller in Device Manager. It
is not a problem in operating the system.
To display correct controller name, run the following command stored in EXPRESSBUILDER
DVD and reboot the system.
Windows Server 2012
Drive letter of optical disk:\001\win\winnt\ws2012\elxfc\friendlyname.exe
Windows Server 2008 R2/Windows Server 2008 64-bit Edition
Drive letter of optical disk:
Windows Server 2008 32-bit Edition
Drive letter of optical disk: