Chapter 3 Appendix
Error Message
AE84
CPU1_DIMM4 with error is
enabled.
AE85
CPU1_DIMM5 with error is
enabled.
AE86
CPU1_DIMM6 with error is
enabled.
AE87
CPU1_DIMM7 with error is
enabled.
AE88
CPU1_DIMM8 with error is
enabled.
AE8D CPU2_DIMM1 with error is
enabled.
AE8E CPU2_DIMM2 with error is
enabled.
AE8F
CPU2_DIMM3 with error is
enabled.
AE90
CPU2_DIMM4 with error is
enabled.
AE91
CPU2_DIMM5 with error is
enabled.
AE92
CPU2_DIMM6 with error is
enabled.
AE93
CPU2_DIMM7 with error is
enabled.
AE94
CPU2_DIMM8 with error is
enabled.
B000
Expansion ROM not initialized There is no space for expanding
Cause
An error in CPU1_DIMM4 was
detected, but because all memory
is currently disabled, this DIMM
was forcibly enabled.
An error in CPU1_DIMM5 was
detected, but because all memory
is currently disabled, this DIMM
was forcibly enabled.
An error in CPU1_DIMM6 was
detected, but because all memory
is currently disabled, this DIMM
was forcibly enabled.
An error in CPU1_DIMM7 was
detected, but because all memory
is currently disabled, this DIMM
was forcibly enabled.
An error in CPU1_DIMM8 was
detected, but because all memory
is currently disabled, this DIMM
was forcibly enabled.
An error in CPU2_DIMM1 occurred,
but because all memory is currently
disabled, this DIMM was forcibly
enabled.
An error in CPU2_DIMM2 occurred,
but because all memory is currently
disabled, this DIMM was forcibly
enabled.
An error in CPU2_DIMM3 occurred,
but because all memory is currently
disabled, this DIMM was forcibly
enabled.
An error in CPU2_DIMM4 occurred,
but because all memory is currently
disabled, this DIMM was forcibly
enabled.
An error in CPU2_DIMM5 occurred,
but because all memory is currently
disabled, this DIMM was forcibly
enabled.
An error in CPU2_DIMM6 occurred,
but because all memory is currently
disabled, this DIMM was forcibly
enabled.
An error in CPU2_DIMM7 occurred,
but because all memory is currently
disabled, this DIMM was forcibly
enabled.
An error in CPU2_DIMM8 occurred,
but because all memory is currently
disabled, this DIMM was forcibly
enabled.
option ROM.
Express5800/B120e-h Maintenance Guide
1. POST Error Message
Solution
Contact your sales representative.
If the board is not used as a boot device,
disable the Option ROM Scan for that
board.
(4/7)
137