NEC Express5800 Series Maintenance Manual page 139

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
th
C066
6
SMBus device Error
detected.
th
C067
7
SMBus device Error
detected.
th
C068
8
SMBus device Error
detected.
C103
BMC core hardware failure.
C104
BMC IBF or OBF check failed. Accessing the BMC address failed.
C105
BMC SEL area full.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC FRU
corrupted.
C10E
BMC SDR Repository empty.
C10F
IPMB signal lines do not
respond.
C110
BMC FRU device failure.
C111
BMC SDR Repository failure.
C112
BMC SEL device failure.
C113
BMC RAM test error.
C114
BMC Fatal hardware error.
C11B
BMC Mezzanine card is not
found.
C11C
BMC Mezzanine partition is
invalid.
C11E
Communication with BMC was
failed in previous boot
C301
SDR mismatch error.
C302
Hardware configuration error. Detected that hardware
C304
Necessary to update SDR
Version for new RAID Card.
C310
Hardware configuration of
cooling is insufficient.
C320
Unmatched PSUs.
C321
System power consumption is
out-of-range in PSUs.
C322
No information for system
power consumption check.
Cause
th
An error occurred in the 6
SM
Bus.
th
An error occurred in the 7
SM
Bus.
th
An error occurred in the 8
SM
Bus.
BMC device (chip) error was
detected.
There is not enough capacity to
write the system event log.
BMC device (chip) error was
detected.
Failure of the SROM for storing
chassis information was detected.
BMC device (chip) error was
detected.
SMC (Satellite Management
Controller) failure was detected.
Failure of the SROM for storing
chassis information was detected.
Failure of the SROM for storing
sensor data record information was
detected.
BMC device (chip) error was
detected.
BMC RAM error was detected.
BMC error was detected.
BMC Mezzanine card is not
mounted.
BMC Mezzanine partition is invalid.
Communication with BMC failed in
previous boot
Inconsistency in the hardware
information of the sensor data
record was detected.
configuration of the server is illegal.
SDR version is not appropriate to
the RAID Controller.
Detected that cooling power is
insufficient in this hardware
configuration.
Detected that unmatched power
supply units are configured.
Detected that system power
consumption exceeds the power
output capacity limit.
Detected that no information was
acquired in checking system power
consumption.
Express5800/B120e-h Maintenance Guide
1. POST Error Message
Solution
Contact your sales representative.
Turn off the power, wait for about 30
seconds, and restart the server. If this does
not resolve the problem, contact your sales
representative.
Start up the Offline Tools and delete the
event logs.
Turn off the power, wait for about 30
seconds, and restart the server. If this does
not resolve the problem, contact your sales
representative.
Turn off the power, wait for about 30
seconds, and restart the server. If this does
not resolve the problem, contact your sales
representative.
Turn off the power, wait for about 30
seconds, and restart the server. If this does
not resolve the problem, contact your sales
representative.
Contact your sales representative.
Unplug the power cord, wait for about 30
seconds, and restart the server. If the same
error persists, contact your sales
representative.
Contact your sales representative.