Cable
NVMe signal cable for front
1
backplane
NVMe signal cable for front
2
backplane
NVMe signal cable for front
3
backplane
NVMe signal cable for front
4
backplane
NVMe signal cable for front
5
backplane
SAS signal cable for front
6
backplane
SAS signal cable for front
7
backplane
NVMe signal cable for rear
8
backplane
Ten 2.5-inch SAS/SATA/NVMe drives, rear SAS/SATA drive assembly, middle NVMe drive assembly
and one 16i RAID adapter
Notes:
• The cable routing illustration is based on the scenario that the rear hot-swap drive cage and middle NVMe
drive assembly are installed. Depending on the model, the rear hot-swap drive cage and middle NVMe
drive assembly might not be available on your server.
• The following two illustrations are for the same one configuration.
ThinkSystem SR635 Maintenance Manual
60
From
NVMe 0–1 connector on the front
backplane
NVMe 2–3 connector on the front
backplane
NVMe 4–5 connector on the front
backplane
NVMe 6–7 connector on the front
backplane
NVMe 8–9 connector on the front
backplane
SAS/SATA 0–3 and SAS/SATA 4–7
connectors on the front backplane
SAS/SATA 8–9 connector on the front
backplane
NVMe connectors on the rear
backplane
To
PCIe connector 1 on the system
board
PCIe connector 2 on the system
board
PCIe connector 3 on the system
board
PCIe connector 4 on the system
board
PCIe connector 5 on the system
board
C0 and C1 connectors on RAID
adapter in PCIe slot 1
C2 connector on RAID adapter in
PCIe slot 1
PCIe connector 6 on the system
board