PREFLIGHT INSPECTION

PRELIMINARY EXTERIOR INSPECTION

Accomplish the Preliminary Exterior Inspection in accordance with the
AFM. See Section 4 for the number and location of covers, tie-downs,
and the rudder gust lock.

COCKPIT/CABIN INSPECTION

Accomplish the Cockpit/Cabin Inspection in accordance with the AFM.
After power on, many systems automatically perform initiated built in
tests (IBIT), as indicated by "Test In Progress" and graying out the pilot
initiated test on the Test Status field, on the Systems Test page. During
this time, abnormal indications may occur on synoptic pages. Pilot
initiated tests can be started after the IBIT has finished and the pilot
initiated tests are no longer grayed out.
The MFD shows a splash screen with software version and database
expiration dates. The pilot should verify the status of each database and
then press the right-most softkey to continue.
Check fuel quantity and balance on the ASI. Set the parking brake and
verify PARKING BRAKE SET indication in the Landing Gear section of
the ASI or on the Status synoptic. Use the STATUS synoptic to verify
that engine oil quantity is NORM, solid state relays and PDU circuit
breakers are NORMAL, both fire bottles are NORMAL, and hydraulic
reservoir quantity is nominal. Refer to AFM Section 4, Oxygen
Consumption, to confirm indicated oxygen quantity, as displayed on
Status synoptic, is sufficient for the planned flight.