2-3. Check of SY-339 Board
Perform the procedures to check if there is any
abnormal state in the SY-339 board.
When the SY-339 board is normal, all procedures in
this section can be performed without problem.
2-3-1. Starting an SY Board Check Software
1. Installation of SY board check software
(1) Start PC.
Copy executable file "SYCheckApplication.exe" from
CD-ROM of an SY board check software to any folder
of PC.
(2) Create the shortcut "SYCheckApplication.exe" in a
desktop.
2. Connection
Connect each equipment referring to the connection
diagram in Section 2-1-2.
n
When using SNC-CS10, attach the vari-focal lens (SNC-
CS11 standard equipment).
3. Setting of camera
(1) Turn on the power of each equipment.
(2) Set the switch (S901) on the rear panel to "NTSC".
(3) Start the "SYCheckApplication.exe" using PC.
The check window is displayed.
SNC-CS10/CS11
(4) Click the [Connect] button on the check window.
(5) Check that the model name is displayed correctly.
When using SNC-CS11: SNC-CS11N
When using SNC-CS10: SNC-CS10N
n
If the model name is not displayed correctly, perform
the procedure from step (1) again.
2-7