Requirements; Environmental Requirements - Motorola IXP-9120 Reference Manual

Table of Contents

Advertisement

Requirements

Requirements
To meet the environmental requirements, the IXP/CPCI-9120 has to be tested in the system
where it is to be installed. Before you power up the board, calculate the power needed accord-
ing to your combination of board upgrades and accessories.

Environmental Requirements

The environmental values must be tested and proven in the used system configuration. The
conditions listed below refer to the surroundings of the board within the user environment.
Note: Operating temperatures refer to the temperature of the air circulating around
the board and not to the component temperature.
Danger Do not operate the product outside the specified environmental limits. High humidity
and condensation may cause short circuits. Make sure the product is completely dry and
there is no moisture on any surface before applying power. Do not operate the product
below 0°C.
Table 5:
Environmental Requirements
Feature
Temperature
Forced air flow
Temp. change
Rel. humidity
Altitude
Vibration
Sinusoidal
Random
44
Operating
0°C to +55°C
300 LFM
± 0.5°C/min
5% to 95% non condensing at +40°C
–300 m to +3,000 m
Level: 5-500Hz 1g
Sweep rate:1 oct/min
Duration:9 sweeps = 60 min/axis
Non-Operating
–40 °C to +85°C
± 1°C/min
5% to 95% non condensing at +40°C
–300 m to +13,000 m
Frequency range:10-2000Hz
Level:0.0045 g2 /Hz
Acceleration:3.03gRMS
Duration: 60 min per axis
Installation
IXP/CPCI-9120

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpci-9120