Programming
instruction
Programming
menu structure
Programming
sub-menu
Basic settings
Display
Diagnosis
Advanced
settings
System
Programming
method
Parameter
editing method
Character/numb
er parameter
programming
Optional
parameter
programming
Page 18
The four keys on the panel can be used to set parameters, debug and
test the instrument, etc.
The menu structure can be seen in
The rightward transition to the horizontal arrow in the figure can be
achieved by the
The downward transition to the horizontal arrow in the figure can be
achieved by the
arrow in the figure can be achieved by the
The basic settings include the following parameters of the meter: Tank
medium, the unit of measurement, the near blanking distance, the
range, the minimum adjustment, the maximum adjustment, the current
output and the sensor tag.
Display Value and Language settings of the meter.
Diagnose and complete the instrument inspection and test function.
For the following: Choose Curve, Show Curve, Start Simulation,
Sensor Status, Measure Status, Peak values and Calibration Date.
Options include False Echo Memory, Failure Mode, Reset to Factory
Settings, Distance Adjust, Echo Threshold, Damping, Envelope Level,
Hart Address and MultiDrop, Damp Time, Max Level Speed, First
Echo, Multi Wave, IF Gain, Tx Power, Rx Gain, 4 mA Adjust, 20 mA
Adjust, Low DK value, Dust.
Include meter information such as Info, Software Version, Latching
Mode, Write Protect.
When the meter is running, press
state and display the programming main menu. After each parameter is
edited, the
invalid.
After editing, press
the running state. At any time of programming, press
abandon programming and exit the programming state of the
parameter item.
When the menu switches to changing a numeric or character value, the
first of those digits highlighted. At this point, you can press
to change the character/number until the desired character/number
appears. Press
can be modified. After programming, press
settings.
Optional parameters are programming items with several selected
parameters for the user to choose. Use
the desired parameter item and press
programming.
SLN 700 SmartLine NCR Level Transmitter User's Manual
Table 5-2
key;
key. The leftward transition to the horizontal
key must be used to confirm, otherwise the edit is
to exit the programming state and return to
key and the next digit is highlighted in turn and
and
Table 5-3.
key.
to enter the programming
to
to confirm the new
key to point the arrow to
to confirm the