Correct And Incorrect Installation Position; Figure 3-6: Correct And Incorrect Installation Position; Figure 3-7: Correct And Incorrect Installation Position - Honeywell SmartLine SLN 700 Series User Manual

Level transmitter, non-contact radar
Hide thumbs Also See for SmartLine SLN 700 Series:
Table of Contents

Advertisement

Correct and incorrect Installation position

Note: sun-shading and rain proof measures should be adopted for the outdoor
installationInstallation of reflecting plate
If there are barriers in the tank, the reflecting plate can be installed to reflect the echo wave away
from the sensor. If necessary, "virtual echo learning" can be turned on.
Revision 1
1. Correct
2. Incorrect: Instruments are installed in the arched or round top of the tank, which will result in
multiple echoes. This should be avoided as much as possible during the installation.

Figure 3-6: Correct and incorrect installation position

1. Incorrect Instruments should not be installed above the fluid in-take , in order to ensure that the
dialectic surface will be detected rather than the charging material flow
2. Correct

Figure 3-7: Correct and incorrect installation position

SLN 700 SmartLine NCR Level Transmitter User's Manual