MD24007 $MC_CHSFRAME_RESET_CLEAR_MASK
Bit 4
When used for measuring or swiveling in JOG, the workpiece reference must be active at
RESET and not cleared (cascaded measuring).
MD24006 $MC_CHSFRAME_RESET_MASK
Bit 4 = 1
MD24007 $MC_CHSFRAME_RESET_CLEAR_MASK
Bit 2 = 0
Bit 3 = 0
Bit 4 = 0
MD24008 $MC_CHSFRAME_POWERON_MASK
Bit 2
Bit 3
Bit 4
MD24080 $MC_USER_FRAME_POWERON_MASK
Bit 0
Application: Zero offset G5xx, including all rotations, should remain active after Power On.
MD28082 $MC_MM_SYSTEM_FRAME_MASK
Bit 2 = 1
Bit 3 = 1
Bit 4 = 1
MD28083 $MC_MM_SYSTEM_DATAFRAME_MASK
Bit 2 = 1
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
System frame workpiece reference
= 0 Do not delete
= 1 Delete
System frame for workpiece reference remains active after RESET
Reserved, do not delete TCARR and PAROT
Reserved, do not delete TOROT and TOFRAME
Do not clear system frame workpiece reference after RESET
System frame rotary table reference (PAROT)
= 0 Do not reset
= 1 Reset
System frame tool reference (TOROT,..)
= 0 Do not reset
= 1 Reset
System frame workpiece reference
= 0 Do not reset
= 1 Reset
= 0 Settable zero offset via Power On not active.
=1 Last active settable zero offset remains active after power on if
MD20152 $MC_GCODE_RESET_MODE[7] = 1
Rotary table reference ($P_PARTFRAME)
Tool reference ($P_TOOLFRAME)
Workpiece reference ($P_WPFRAME)
Rotary table reference ($P_PARTFRAME)
Technologies and cycles
Clear system frames after RESET
Active system frames after RESET
Clear system frames after RESET
Reset system frames after Power On.
Settings for settable frames.
Setting-up system frames (SRAM)
Setting-up data management, system
frames (SRAM)
21.7 Swiveling
565