Procedure
Extended reset
If you wish to carry out a warm restart only for specific objects or specific areas, then additional
softkeys are available for this purpose.
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
1.
Select the "Start-up" operating area.
2.
Press the "Mach. data" softkey.
The "Control unit parameters", "Supply MD" and "Drive MD" softkeys are
displayed.
3.
Press the softkey of an area to show its parameters.
4.
Place the cursor on the desired parameter.
5.
Position the cursor on the entry to be modified and enter the required
value.
6.
In order to activate the settings, you have the option of saving or carrying
out a reset.
Press the "Save/reset" softkey.
7.
Press the "Save" softkey.
You are prompted "What do you wish to save?"
You can make the following selection per softkey:
● Actual drive object
● Drive unit
● Drive system
- OR -
Press the "Reset (po)" softkey.
You are prompted as to whether you wish to initiate a warm restart for the
NCK and the complete drive system.
Confirm the prompt with the "Yes" softkey.
Reject the warm restart with the "No" softkey.
Press the "Extended reset" softkey.
You are prompted to enter for which objects you wish to initiate a warm
restart.
You can make a selection with the following softkeys:
Only the NCK is restarted.
Machine and setting data
7.5 Displaying/editing drive parameters
101