Color
Purple
Beep Control (available for Wiegand Protocol)
Gray
Case Sensor (available for Wiegand Protocol)
Green
Wiegand W0 (available for Wiegand Protocol)
White
Wiegand W1 (available for Wiegand Protocol)
Black
GND
Orange
Red LED Control (available for Wiegand Protocol)
Red
PWR (DC +12V)

2.4 Wiring Cables

Purpose:
Wire the cables between controller and card reader, thus to
establish the communication between them.
Steps for RS-485 communication mode:
1.
Set the DIP switch of No. 6 as 0.
2.
Set the DIP switch of No. 1 ~ 5 for RS-485 address and
reading card mode. For details, please refer to 2.2
Introduction for DIP Switch.
3.
Wire the cable between controller and card reader as
shown below.
DS-K1100 Series Card Reader