Start Procedures; Restart Procedures - Honeywell 200 Series Hardware Manual

Table of Contents

Advertisement

SECTION IV.
TYPE 214-1 CARD PUNCH
Start Procedures
~
1.
To perform an initial start following a central processor power up:
a.
Press the POWER ON switch.
b.
Press the RUNOUT switch.
This action resets error-check
conditions and clears the card path.
c.
Load the input deck into the input hopper face down, nines edge
fir st.
d.
Press the START switch.
If it is desired to stop the punch while
punching operations are in progress, the STOP switch may be
pressed.
Restart Procedures
1.
To restart following a STOP switch depression (a normal stop with no error
conditions indicated):
a.
Press the START switch.
2.
To restart following a stop condition for a CARDS indication:
a.
Refill the empty input hopper or empty the full output stacker
as required, and/or insure the cards are pressed against the
stacker -pres sure switch.
NOTE: When the punch is running, care should be taken in
removing cards from the output stacker to avoid a
possible CARDS indication and a subsequent halt.
b.
Press the START switch.
3.
To restart following a stop condition for an INPUT indication:
a.
Remove the remaining cards from the input hopper.
The cards
causing the feed failure are nearest the throat (as the deck is
removed).
These cards mayor may not be damaged or bent
out of shape.
b.
If the cards are damaged or bent out of shape, they should be
replaced with new cards.
c.
Place the deck in the feed hopper and resume punching from the
point in the program at which the stop occurred.
d.
Press the START switch.
NOTE: It is.usually not necessary for the operator to remove the
top cover when performing corrective action for a feed
failure.
4.
To restart following a stop condition for a TRANSPORT indication:
a.
Raise the hinged top cover and clear the jam condition as required.
NOTE: It is possible for the card causing the jam condition to
be in a position where
it
cannot be seen by the operator,
e. g., near the output stacker; care must be exercised
to insure that the entire transport mechani sm has been
cleared.
b.
The transport motors are turned off during a TRANSPORT indi-
cation.
They must be turned on before the RUNOUT switch is
4-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

120121