S4 Beam Programming Base Interface; How To Change The Mode Of An S4 Beam - Honeywell GENT S4 Data And Installation

Beam sensor & brackets (for vigilon and nano systems)
Hide thumbs Also See for GENT S4:
Table of Contents

Advertisement

S4 Beam Sensor & brackets

S4 Beam Programming Base Interface

software
The S4 Beam programming base interface
application can be downloaded from Gent Expert
(http://gentexpert.co.uk/). Once the software is
downloaded onto your computer simply Run the
setup.exe of the application.
The installation of software will check to see if the
computer has .netframework 3.5 with
Service pack 2 installed and will automatically install
these from the internet if the computer is connected
to the internet.
"
Allow sufficient time for the installation of
.netframework 3.5 with Service pack 2
take several minutes.

How to change the mode of an S4 Beam

Sensor pair
Using this programming tool and software application
on your laptop you can change an S4 beam sensor
pair to be backward compatible with 34740 beam
sensor pair. The tool also allows conversion from a
backward compatible S4 beam sensor back to its
original factory set mode.
Ensure the S4 beam sensor is correctly and
a.
securely fitted into the programmable base.
Connect the power and communication leads to
the programmable base and computer as
shown, then switch ON the mains power. Note
the outside LEDs on the Beam sensor will flash
on power up.
Click on the S4 Programming Base Interface
b.
icon on your desktop to run the application.
4188-968 issue 4_Part 2_07-12_S4 mains interface
Click on the S4 Beam tab.
c.
d.
The Device information
k
to the Programming base is detected.
¡ The Device information
, as this will
'S4 Beam Mk II V1.00 19/05/09'
¡ An original S4 beam sensor device will show
its Operating mode as:
¡ A Backward Compatible S4 Beam sensor will
show its Operating mode as:
Active'
e.
Select the Change mode button
S4 Beam Sensor mode.
f.
The Status message
'Waiting for write confirmation' and on
completion of the configuration it will read
'eeprom write completed' followed by a
n
The Operating mode will show the respective
compatibility message. A cross at
failure to convert the beam sensor, so power
down the programming base, remove the beam
sensor from base and repeat steps a. to f.
There is no need to power down the
programming base to program the next beam
sensor.
Commissioning information
S4 Beam Mk II V1.00 19/05/09
S4 Beam mode - Active
eeprom write complete
j
will provide a message once the device fitted
'S4 Beam mode - Active'
'Backward compatible Beam sensor -
k
.
m
to the right of the Change mode button
and Operating mode
j
will always read
k
.
l
to switch the
will initially read
l
.
n
indicates
17

Advertisement

Table of Contents
loading

Table of Contents