17.2 Product Safety Agency Certifications

17.2.1 Canadian Standards Association (CSA)

ANSI/ISA S82.02.01 (61010-1) CSA C22.2 No. 1010-1, ANSI/UL 61010-1, Safety Standard for Electrical Equipment for
Measurement, Control and Laboratory Use – Part 1: General Requirements
C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II
C22.2 No. 25, Enclosures for Use in Class II, Group E, F & G Hazardous Locations
C22.2 No. 94, Special Purpose Enclosures, Industrial Products
C22.2 No. 14, Industrial Control Equipment, Industrial Products
C22.2 No. 30, Explosion Proof Enclosures for Use in Hazardous Locations, Industrial Products
C22.2 No. 157, Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations
C22.2 No. 213, Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations
E60079-0, Electrical Apparatus for Explosive Gas Atmospheres, Part 0: General Requirements
E60079-1, Electrical Apparatus for Explosive Gas Atmospheres, Part 1: Flameproof "d"
E60079-11, Electrical Apparatus for Explosive Gas Atmospheres, Part 11: Intrinsic Safety "i"
E60079-15, Electrical Apparatus for Explosive Gas Atmospheres, Part 15: Electrical Apparatus With Type of Protection "n"
Temperature code: T4 (135°C) based on the maximum specified ambient of 85°C.

17.2.2 Factory Mutual (FM)

ANSI/ISA S82.02.01 (61010-1) CSA C22.2 No. 1010-1, ANSI/UL 61010-1, Safety Standard for Electrical Equipment for
Measurement, Control and Laboratory Use – Part 1: General Requirements
FM electrical equipment requirements for use within Class I, Division 2, Groups A, B, C and D/Zone 2, Group IIC Hazardous
Locations.
Factory Mutual Approval Standard Class No. 3600, "Electrical Equipment for Use in Hazardous (Classified) Locations –
General Requirements
Factory Mutual Approval Standard Class No. 3810, "Electrical and Electronic Test, Measuring, and Process Control
Equipment
Factory Mutual Approval Standard Class No. 3611, "Electrical Equipment for Use in Class I, Division 2, Class II, Division 2
and Class III, Division 1 and 2 Hazardous (Classified) Locations
Temperature code: T4 (135°C) based on the maximum specified ambient of 85°C.
OneWireless XYR 6000 Transmitter
Professional Installation Guide
Honeywell Proprietary
50021956
Rev B
27 August 2008