Split/Dual Reporting
∗ ∗ ∗ ∗ 49
0 = Standard/backup reporting only (all
to primary)
1-5 = see table at right
Burglary Dialer Delay
∗ ∗ ∗ ∗ 50
Delay Time:
0 = no delay
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
V20PSIA/V15PSIA:
Delay Time:
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
Delay Disable:
0 = use delay set in entry 1
1 = dial delay disabled for zones
listed in zone list 6 (use zone list 6
to enter those zones that require
dial delay to be disabled; these
zones ignore the setting in entry 1)
UL: Dial delay plus entry delay must not
exceed one minute; use zone list 6 to
disable dial delay from appropriate zones,
if necessary.
∗ ∗ ∗ ∗ 53
SESCOA/Radionics Select
0 = Radionics (0-9, B-F)
1 = SESCOA (0-9 only reporting)
Dynamic Signaling Delay
∗ ∗ ∗ ∗ 54
0 = no delay (both signals sent)
1 = 15 secs
2 = 30 secs, etc.
UL: If using line security, must be 0.
Reports will be sent to both the dialer and
the communication device.
∗ ∗ ∗ ∗ 55
Dynamic Signaling Priority /
AAV Path Select
0 = Primary Dialer first / AAV via phone
line
1 = Communication Device (LRR) first /
AAV via communication device
path (see AAV Path Select
paragraph at right)
For UL Commercial Burglary installations
that use a DACT and LRR, this field must
be 0.
[0]
Backup Reporting: All reports are sent only to the primary number
unless unsuccessful after 8 attempts. If unsuccessful, the system will
make up to 8 attempts to send all reports to the secondary number. If
still unsuccessful after the 16 attempts, the system displays the
"COMM. FAILURE" message (FC for fixed-word displays).
Primary Phone No.
1 = Alarms, Restore, Cancel
2 = All except Open/Close, Test
3 = Alarms, Restore, Cancel
4 = All except Open/Close, Test
5 = All
[2,0]
Delay
V20PSIA/V15PSIA
Time
Delay Disable
Provides delay of "BURGLARY ALARM" report to the central station,
which allows time for the subscriber to avoid a false alarm transmission.
This delay does not apply to zone type 24 alarms (silent burglary) or to
24-hour zone types 6, 7, and 8 (silent panic, audible alarm, auxiliary
alarm), which are always sent as soon as they occur.
UL: Delay Time must be 0
SIA Guidelines: delay must be minimum of 15 seconds
[0
Enter 0 for all non-SESCOA formats.
[0]
Select delay from 0 to 225 secs, in 15-sec increments.
Intended for reporting via a communication device on the ECP bus
(LRR). This field lets you select the time the panel should wait for
acknowledgment from the first reporting destination (see ∗55) before it
attempts to send a message to the second destination. Delays can be
selected from 0 to 225 seconds, in 15-second increments. This delay is
per message. If 0 is entered in this field, the control panel will send
redundant reports to both Primary Dialer and communication device.
[0]
This field selects the primary communication path for reporting (dialer
or communication device) of primary phone number events
Split/Dual Reporting) and selects the communication path used for
AAV sessions (phone line or communication device path). Use ∗29
IP/GSM menu mode to enable the communication device being used.
Reports intended for the secondary phone number are not sent via
the communication device.
For Dynamic Signaling Priority: Select the initial reporting destination
for messages as follows:
Primary Dialer First selected ( 0 ):
• If acknowledged before delay expires (see ∗54), then message will
not be sent via LRR.
• If not acknowledged before delay expires, message is sent to both
the Primary Phone No. and via LRR.
Communication Device (LRR) First selected ( 1 ):
• If acknowledged before delay expires, then message will not be sent
to the primary dialer.
• If not acknowledged before delay expires, message is sent to both
the Primary Phone No. and via LRR.
– 8 –
2nd Phone No.
Others
Open/Close, Test
All
All
(see ∗49