Honeywell Vista-20P Quick Start Manual
Honeywell Vista-20P Quick Start Manual

Honeywell Vista-20P Quick Start Manual

Wired alarm control panel
Hide thumbs Also See for Vista-20P:

Advertisement

NOTE: DO NOT hook power to the keypad until the entire system is installed and
ready for programming. Reason: You have to make a programming change to
each keypad upon 30 seconds of power being sent to the keypad.
Upon 50 seconds of power up, you will need to press and hold * and # at
Exit Programming=*99 or 00 depending on where you are at
Step 1: Assign Keypad Address
 Within 30 seconds of the main keypad receiving power: Press and hold
the 1 and 3 buttons at the same time.
 Con Addr = will appear and you will need to enter 16. Then press *
 On each additional keypad you will need to enter a unique address: 17,
18, etc.
o Do Not Duplicate Keypad Addresses. Keypads have to be
addressed 16 to 23 (no duplicates), but come defaulted at 31 and
will not work until they are re-addressed.
Step 2: Enter Programming
After the keypad is addressed, you will need to enter programming:
 Enter 4112 800
 Field 20 (Installer Code) will be displayed on the screen.
 We can begin programming from this point.
Step 3: Default the Entire System (*97)
 Enter *97 to default your system. The system will beep. This will ensure
that there is a clean slate to start from.
 If you will be using central station monitoring: Press *96 and the system
will beep. This is for clearing the ID number for Central Station.
Step 4: Installer Code (*20)
 If you would like to change the installer code, press *20 + new installer
code. Be sure not to forget this number.
Quick Start Guide
Vista-20P
Installer Code = 4112
Master Code=1234
Program Mode= 4112+800
Or
same time.
*=Change Data
#=View Data

Advertisement

loading

Summary of Contents for Honeywell Vista-20P

  • Page 1 Quick Start Guide Vista-20P NOTE: DO NOT hook power to the keypad until the entire system is installed and ready for programming. Reason: You have to make a programming change to each keypad upon 30 seconds of power being sent to the keypad.
  • Page 2 Step 5: Exit Delay (*34) (Page 4-2 in the Installation and Setup Guide) The minimum delay is 45 seconds. If the delay is between 45 and 96 seconds, then enter the actual seconds. If the delay time is more than 96 seconds, then enter 97 and then the system will give you a delay of 120 seconds.
  • Page 3 Step 8: Confirmation of Arming Ding (*38) (Page 4-2 in the Installation and Setup Guide)  Note: You do not need to enter *38 if you have just completed step 7.  Enter: o 00=No Ding o 01=Ding after Arming o 02=Ding after arming with RF button or RF keypad Step 9a: Hardwired Zone Programming (*56) (Page 5-1 and 5-2 of the Installation and Setup Guide)
  • Page 4  Summary Screen will appear. Press * to continue or # to go back to make changes.  At this time we will not enter Alpha Descriptors. We recommend using *82 for this. (Page 9-1 of the Installation and Setup Guide) Press “0” ...
  • Page 5 Step 10: Dialer Delay (*50)  Enter 0 for no dialer delay Step 11: Changing the Master Code and User Codes Changing the master code  Enter the Master code + 8 + 02 + New Code + the New Code again. The keypad will beep 1 time for confirmation letting you know the code was successfully changed.
  • Page 6 Step 6: If you address your keypad 17, enter programming mode by entering “installer code + 800”. Field 20 (Installer Code Field) will be displayed. Enter data field “*190”. Then enter “1 0” to enable your keypad. Then enter *99 to exit. Programming Function Keys: *57 Function Key Programming Defaults...