Honeywell ADEMCO VISTA SERIES Programming Manual page 15

Hide thumbs Also See for ADEMCO VISTA SERIES:
Table of Contents

Advertisement

Pager Delay Option For Alarms
∗ ∗ ∗ ∗ 172
0 = none
1 = 1 minute
2 = 2 minutes
3 = 3 minutes
MISCELLANEOUS SYSTEM FIELDS (*174-*181)
∗ ∗ ∗ ∗ 174
Clean Me Reporting Options
0 = disable
1 = Clean Me signal reports
∗ ∗ ∗ ∗ 177
Device Duration 1, 2
0 = 15 secs 6 = 2-1/2 min #+11 = 7 min
1 = 30 secs 7 = 3 min
2 = 45 secs 8 = 4 min
3 = 60 secs 9 = 5 min
4 = 90 secs #+10 = 6 min #+15 = 15 min
5 = 2 min
50/60 Hertz AC Operation
∗ ∗ ∗ ∗ 181
0 = 60 Hz; 1 = 50 Hz
CONFIGURABLE ZONE TYPE OPTIONS (*182-*185)
(see Configurable Zone Type Worksheet following data field ∗199)
• The system allows you to define custom zone types (VISTA-20P supports 4 [types 90-93]; VISTA-15P supports 2 [types 90,
91]) based on the options selected.
• All configurable zone types can be programmed via the downloader. Zone types 90-91 can also be programmed from a
keypad using data fields *182-*185.
• IMPORTANT: Be careful when selecting combinations of options for configurable zone types. Contradictory options can
cause unpredictable results.
Configurable Zone Type Options
Auto Restore (entry 2): Faults on zones set for this option are cleared; restore messages sent upon restoral of faults.
Vent Zone (entry 2): Zones set for this option are ignored if faulted when arming the system, but are protected if the zone is later restored
(e.g., an open window can be ignored when arming, but if the window is later closed, it will be protected; opening the window again causes an
alarm.)
Bypass Disarmed (entry 4): Zones set for this option can be bypassed only while the system is disarmed.
Bypass Armed (entry 4): Zones set for this option can be bypassed when the system is armed.
Dial Delay (entry 6): Alarms on zones set for this option participate in dial delay central station reporting, if system dial delay enabled in field
*50.
Fault Delay (entry 6): Faults on zones set for this option are delayed by the time set in field *87. Do not use this option if using entry/exit
delay for this zone type.
Faults Display (entry 7): Selects how faults on zones set for this zone type are displayed.
Power Reset/Verification(entry 7): Selects whether the system resets power (when user enters code + OFF), and whether the system
performs alarm verification (see description for zone type 16 in Zone Type Definitions section) when a fault occurs on these zones.
Use Entry Delay (entry 8): Selects whether to use the system's entry delay times.
Use Exit Delay (entry 8): Selects whether to use the system's exit delay time.
Interior Type (entry 8): Zones set for this option are treated same as standard zone type 4 (bypasses when armed STAY, faults displayed).
Alarm Sounds (entry 9): Selects the type of alarms sound for zones set for this zone type.
Bell Timeout (entry 9): Alarm sounding on zones set for this option remain for the duration set in fields *32 / *33.
Fire Zone (entry 9): Zones set for this option respond in the same manner as if programmed for zone type 9. Do not set fire zones to respond
as a "fault" in entries 1-6.
Trouble Sounds (entry 10): Selects the type of trouble sounds for zones set for this zone type (periodic beeps = once every 30 seconds;
trouble beeps = rapid beeping).
Chime Enable (entry 10): Zones set for this option cause a chime when Chime mode is on.
[3]
This field determines the delay of alarm reports to the pager. This gives
the Central Station enough time to verify the alarm report it received
before the dialer attempts to dial the pager.
This delay is for ALL pagers in the system.
[0]
For ESL smoke detectors
This is a maintenance feature for ESL 2-wire smoke detectors on Zone
1. If used, this option limits the number of smoke detectors to a
maximum of 10, rather than 16. To enable the "clean me" feature, a
time response setting of "3" (1.2 seconds) must be entered in ∗56 Zone
Programming for zone 1.
NOTE: If Clean Me is enabled, you must enter "3" in field ∗56
programming for zone 1 response time.
1
2
#+12 = 8 min
(used in *80 Menu mode-Device Actions 5/6)
#+13 = 10 min
These entries set the duration for output action options 5 (duration 1)
#+14 = 12 min
and 6 (duration 2) programmed in ∗80 Output Function Programming.
[0]
Select the type of AC power applied to the control (option is used for
Real-Time Clock synchronization)
– 15 –
[0] [0]