Honeywell ADEMCO VISTA SERIES Programming Manual page 17

Hide thumbs Also See for ADEMCO VISTA SERIES:
Table of Contents

Advertisement

Keypad 2 Device Address 17
∗ ∗ ∗ ∗ 190
Entry 1: Partition/ Enable
VISTA-20P: Enter partition in which the
keypad is located where:
For Touchscreen device usage
0 = disable
1 = partition 1
2 = part. 2
3 = part. 3 (common)
For Remote Services device usage
5 = part. 1 (auto-stay arm disabled)
6 = part. 2 (auto-stay arm disabled)
7 = part. 3 (common; auto-stay arm
disabled)
VISTA-15P:
For Touchscreen device usage
0 = disable
1 = enable
For Remote Services device usage
5 = auto-stay arm disabled
Entry 2: Sound
0 = no suppression
1 = suppress arm/disarm and Entry/Exit
beeps
2 = suppress chime beeps only
3 = suppress arm/disarm, Entry/Exit,
and chime beeps
Keypad 3 Device Address 18
∗ ∗ ∗ ∗ 191
See field ∗190 for entries.
Keypad 4 Device Address 19
∗ ∗ ∗ ∗ 192
See field ∗190 for entries.
∗ ∗ ∗ ∗ 193
Keypad 5 Device Address 20
See field ∗190 for entries.
∗ ∗ ∗ ∗ 194
Keypad 6 Device Address 21
See field ∗190 for entries.
∗ ∗ ∗ ∗ 195
Keypad 7 Device Address 22
See field ∗190 for entries.
Keypad 8 Device Address 23
∗ ∗ ∗ ∗ 196
See field ∗190 for entries.
Exit Time Display Interval
∗ ∗ ∗ ∗ 197
0 = no display
1-5 = seconds between display refresh
TOUCH SCREEN DEVICE NOTE: If
using more than one touch screen device
(e.g., 6270, Symphony) with the system,
leave field *197 Exit Time Display Interval
set to the default value "0." The 6270
automatically displays remaining exit time
in one-second increments.
Display Partition Number
∗ ∗ ∗ ∗ 198
0 = no
1 = yes (part. no. appears on display)
ECP Fail Display
∗ ∗ ∗ ∗ 199
0 = 3-digit display
"1" + device address)
1 = 2-digit fixed-display as "91
[0] [0]
Partition/
Sound
Enable
Entry 1 - Partition/Enable: Enter the desired option for the keypad's
home partition.
Note for Remote Services Devices: If using the Remote Services
feature of the communication device, select an option 5-7 (option 5 for
VISTA-15P), depending on the partition the Remote Services device is
associated with (these options automatically disable auto-stay arming
when the system is armed from the respective Remote Services
device). Refer to the communication device's installation instructions
for details on enabling the Remote Services feature.
Entry 2 - Sound: Enter the desired sound option for this keypad.
[0] [0]
Part./ Enable
Sound
[0] [0]
Part./ Enable
Sound
[0] [0]
Part./ Enable
Sound
[0] [0]
Part./ Enable
Sound
[0] [0]
Part./ Enable
Sound
[0] [0]
Part./ Enable
Sound
[0]
If enabled, keypads display the exit time remaining after arming the
system, updated at the interval selected (i.e. if the exit delay is 30
seconds and "2" is selected in this field, the keypad display refreshes
every 2 seconds, displaying 30, 28, 26, 24, etc.).
An interval greater than "1" may be necessary for some older keypads
to allow users time to enter key presses between display updates.
NOTE: If enabled and using only 2-digit fixed-word keypads (e.g.,
6150RF), do not set exit delay time greater than 96 seconds. Using a
longer delay time may cause end-user confusion because 2-digit
display keypads cannot display times greater than "99." If longer exit
time is required by the installation, it is recommended that the Exit
Time Display option be disabled ("0").
(VISTA-20P; for Alpha Display Keypads)
[0]
If selected, the partition number is displayed in the upper-left corner of
the alpha display. This is useful when using the GOTO partition function.
[0]
Select "0" if using Alpha keypads and/or 3-digit Fixed-Word Display
keypads. ECP faults will display "1" plus the device address (00-15) of
device causing the fault (e.g., faults on device 07 display as "107").
Select "1" if using 2-digit Fixed-Word Display keypads (e.g., certain
6128 series keypads). If selected, ECP faults for all devices will display
as "91" on 2-digit displays, and "191" on 3-digit or Alpha keypads.