Honeywell ADEMCO VISTA SERIES Programming Manual page 23

Hide thumbs Also See for ADEMCO VISTA SERIES:
Table of Contents

Advertisement

Confirm
XMIT TO CONFIRM
[∗] to continue
PRESS
TO SKIP
,
Not Confirmed
Entd A022-4063
[∗] to continue
Rcvd A022-4064
SERIAL #2
LOOP 1
SERIAL #1
LOOP 3
SERIAL #2
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 2
5834-4 Wireless Key
Transmitter
NOTE: Some transmitters are not intended for use in UL installations.
For Button-Type Devices
TEMPLATE 1
Loop
1
2
3
4
TEMPLATE 2
Loop
1
2
3
4
Loop
TEMPLATE 3
1
2
3
4
Wireless Key Predefined Default Templates
SERIAL #1
LOOP 2
LOOP 4
SERIAL #2
LOOP 4
SERIAL #1
LOOP 1
5834-013-V0
5804 Wireless Key
Transmitter
Function
Zone Type
No Response
23
Disarm
22
Arm Away
21
No Response
23
Function
Zone Type
No Response
23
Disarm
22
Arm Away
21
Arm Stay
20
Function
Zone Type
24-hour audible
7
Disarm
22
Arm Away
21
Arm Stay
20
If "Yes" was entered at the SET TO CONFIRM? prompt
previously (see first prompt following entry into the ∗58
Expert Programming Mode), the display on the left will
appear. Confirm serial and loop numbers by activating the
wireless key.
IMPORTANT:
When confirmed, the key is not active for arming/disarming until
it is assigned to a user number (using the assigning attributes
command, attribute "4"). See System Operation section for
procedure.
If the serial number transmitted does not match the serial
number entered, a display similar to the one shown will appear.
If the loop number does not match, it will also be displayed.
If so, activate the button on the wireless key once again. If a
match is not obtained (i.e., summary display does not appear),
press the [#] key and then enter the correct serial number.
If the serial number transmitted matches the serial number
entered, the keypad will beep 3 times and will return you to the
Zone Number prompt to enter the starting zone for the next
wireless key.
Or you can return to *58 Menu mode by pressing 00 at the Zone
Number prompt.
LOOP 3
LOOP 2
RED/YELLOW
LOOP 1
5804-001-V4
For Button-Type Devices
TEMPLATE 4
Loop
1
2
3
4
TEMPLATE 5
Loop
1
2
3
4
Loop
TEMPLATE 6
1
2
3
4
– 23 –
GREEN/YELLOW
LED
LOOP 2
LED
LOOP 3
• •
• • •
• •
• •
• •
ENROLL AS "BR"
5804BD 2-Way Wireless Key
Transmitter
Function
Zone Type
No Response
23
No Response
23
Arm Away
21
Disarm
22
Function
Zone Type
No Response
23
Arm Stay
20
Arm Away
21
Disarm
22
Function
Zone Type
24-hour audible
7
Arm Stay
20
Arm Away
21
Disarm
22
LOOP 4
LOOP 1
5 8 0 4 B D - 0 0 7 - V 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents