Honeywell ADEMCO VISTA SERIES Programming Manual page 27

Hide thumbs Also See for ADEMCO VISTA SERIES:
Table of Contents

Advertisement

80 Menu Mode
Output Funct. #
(00 = Quit)
01
01
A E P Trig
?00 0
0 – ZL=00
01 Activated By:
Zone List
A"
01 Zn List
1
"B"
01 Enter Zn type
Perimeter
03
Output Function No.
(VISTA-20P: 01-48
(VISTA-15P: 01-24)
[∗] to continue; 00 to quit
Summary Screen
[∗] to continue
Activated By
0 = delete
1 = zone list (go to "A")
2 = zone type (go to "B")
3 = zone number (go to "C")
[∗] to continue
Zone List
01-08 = zone list
[∗] to continue
Zone Type
See list at right for available
zone types.
Enter the output function number to be defined (or 00 to exit)
This screen displays a summary of the current output
programming (for this example, Zone List has been selected-this is
the default screen).
A = Output Action; E = Triggering event; P = Partition;
Trig = Trigger type
NOTE: A question mark in the summary screen indicates that the
device number shown has not been mapped. Use *79 Menu mode
to map the device.
Select where the initiating event for this output definition is to occur
as follows:
If you enter "0," the following prompt appears:
Delete?
0 = NO, 1 = YES
Press 1 to delete this output definition. The system deletes the
output function and any previous programming.
(prompt appears if zone list was selected)
Enter the desired zone list number associated with this output
number. At the ENTER EVENT prompt, enter the zone list event
that will activate this output
NOTE: Do not use pager zone lists 09-12 in output definitions.
Enter Event
0 = restore; 1 = alarm;
Alarm
1
2 = fault; 3= trouble
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output, but ALL zones in the list must be restored
before the output is restored.
Press [ , ] to continue and skip to the "Output Action" prompt.
(prompt appears if zone type was selected)
Enter the desired zone type associated with this output number. At
the PARTITION prompt, enter the partition in which this zone type
will occur.
CHOICES FOR ZONE TYPES:
00 = Not Used
05 = Day/Night
01 = Ent/Exit #1
06 = 24 Hr Silent
02 = Ent/Exit #2
07 = 24 Hr Audible
03 = Perimeter
08 = 24 Hr Aux
04 = Interior Follower
09 = Fire
10 = Interior w/Delay
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay
36 = **At Bell Timeout***
21 = Arming–Away
38 = Chime
22 = Disarming
39 = Any Fire Alarm
31 = End of Exit Time
40 = Bypassing
32 = Start of Entry Time 41 = **AC Power Failure
33 = Any Burglary Alarm 42 = **System Battery Low
43 = Comm. Failure
52 = Kissoff
54 = Fire Zone Reset
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function "07").
†† when used with an output function, the carbon monoxide zone type
activates upon CO alarms only. Does not activate for trouble conditions.
§ automatically set when appropriate AVS Quick Command performed.
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition
0 = any partition; 1 = partition 1;
Any partition 0
2 = partition 2; 3 = common
Press [ , ] to continue and skip to the "Output Action" prompt.
– 27 –
12 = Monitor Zone
14 = Carbon Monoxide††
16 = Fire w/verification
23 = No Alarm Response
24 = Silent Burglary
77 = Keyswitch Zone
81 = AAV Monitor Zone
90-91 = Configurable
58 = Duress
60 = AAV
61 = AVS/GSMV
session begin
62 = AVS/GSMV
session end
66 = Function Key†
67 = Bell Fail
68 = Telco Line Cut
78 = Keyswitch Red LED
79 = Keyswitch Green LED
§
§