Detector Type
Gas
Oxygen
SPLIO1...
Flammable (CAT)
SPLIF6...
Carbon Monoxide
SPLIC1...
Hydrogen Sulfide (low range)
SPLIH1...
Hydrogen Sulfide (high range)
SPLIH2...
Hydrogen
SPLIG1...
Sensor Operating Temperature
Gas
Min
Oxygen
−20 °C
Flammable (CAT)
−20 °C
Carbon Monoxide
−20 °C
Hydrogen Sulfide (low range)
−20 °C
Hydrogen Sulfide (high range)
−20 °C
Hydrogen
−20 °C
User Selectable
User Selectable Cal
Default Range
Range
Gas Range
Fixed, 25.0% vol
25.0% vol
Fixed
20 to 100% LEL
100% LEL
20 to 70% of
50 to 1000 ppm
300 ppm
selected full scale
10.0 to 50.0 ppm
50.0 ppm
range
50 to 200 ppm
100 ppm
1000 ppm only
1000 ppm
Fixed
Default A1 Type
Max
A1
Rising
50 °C
23.5% vol
Rising
50 °C
20% LEL
30 ppm
Rising
50 °C
50 °C
10 ppm
Rising
10 ppm
Rising
50 °C
200 ppm
Rising
50 °C
Response Time
Default Cal Point
Resolution
t90 (s)
20.9% vol
< 30
0.1% vol
50% LEL
< 30
1% LEL
100 ppm
< 40
25.0 ppm
0.1 ppm
< 40
25 ppm
< 40
500 ppm
< 105
Default Alarm Points & Types
A1 Options
Default A2 Type
A2
Rising/Disabled
Falling
19.5% vol
Rising/Disabled
Rising
50% LEL
Rising/Disabled
100 ppm
Rising
Rising/Disabled
20 ppm
Rising
Rising/Disabled
20 ppm
Rising
Rising/Disabled
400 ppm
Rising
Accuracy
( ppm or % of applied gas which is the greater)
< ±0.6 %vol
< ±5 %LEL
1 ppm
< ±2 ppm or ±20%
< ±0.3 ppm or ±20%
1 ppm
< ±5 ppm or ±20%
1 ppm
< ±8 ppm or ±20%
LAL
A2 Options
Falling/Disabled
5.0% vol
Rising/Disabled
10% LEL
Rising/Disabled
15 ppm
Rising/Disabled
1.0 ppm
Rising/Disabled
5 ppm
Rising/Disabled
100 ppm
LDL
20.6 to 21.2% vol
0 to 3.0% vol
6% LEL
13 ppm
0.8 ppm
1 ppm
30 ppm