Configuring the Module Using the ICIM,
Configurable Parameters
Configurable parameters for the module include the following.
FHEDA Configurable Parameters
FHEDA Control
Enable
Atten
Equal
Master
NomRfIn
NomRfOut
RHEDA Configurable Parameters
RHEDA Control
Enable
Atten
Master
NomRfIn
NomRfOut
3-20
Continued
Function
Amplifier On/Off
Pin Attenuator
Signal Equalization
Master/Slave.
When set to Slave,
amplifier begins
operation with external
alarm signal
Sets value of nominal
Rf Input level
Sets value of nominal
Rf Output level
Function
Amplifier On/Off
Pin Attenuator
Master/Slave.
When set to Slave,
amplifier begins
operation with external
alarm signal
Sets value of nominal
Rf Input level
Sets value of nominal
Rf Output level
Operation Using ICIM
Values
On or Off
0 to 10.0 dB (0.5 dB
steps)
0 to 9.0 dB (1.5 dB
steps)
Master/Slave
20 to 40 dBmV (0.5 dB
steps)
40 to 60 dBmV (0.5 dB
steps)
Values
On or Off
0 to 10.0 dB (0.5 dB
steps)
Master/Slave
10 to 40 dBmV (0.5 dB
steps)
30 to 60 dBmV (0.5 dB
steps)
78-4006323-01 Rev C
Default
On
0 dB
0 dB
Master
32.0 dBmV
52.0 dBmV
Default
On
0 dB
Master
32.0 dBmV
42.0 dBmV