Modifying Module Alarm Limits - Cisco Prisma II Installation And Operation Manual

Forward and reverse headend driver amplifiers
Hide thumbs Also See for Prisma II:
Table of Contents

Advertisement

Modifying Module Alarm Limits

Introduction
Using LCI, you can modify alarm limits for several parameters. FHEDA parameters
whose alarm limits you can change are listed below.
Alarm
Rf Input Power
Rf Input Power
Rf Input Power
Rf Input Power
Rf Output Power
Rf Output Power
Rf Output Power
Rf Output Power
78-4006323-01 Rev C
Alarm Condition
Minor Low
Rf Input <-7.0
dBmV below
nominal setting
Minor High
Rf Input >7.0
dBmV above
nominal setting
Major Low
Rf Input <-15.0
dBmV below
nominal setting
Major High
Rf Input >15.0
dBmV above
nominal setting
Minor Low
Rf Output <-7.0
dBmV below
nominal setting
Minor High
Rf Output >7.0
dBmV above
nominal setting
Major Low
Rf Output <-15.0
dBmV below
nominal setting
Major High
Rf Output >15.0
dBmV above
nominal setting
Operation Using LCI
Range
Possible Cause
Input below
nominal setting
Input above
nominal setting
Input below
nominal setting
Input above
nominal setting
Output below
nominal setting
Output above
nominal setting
Output below
nominal setting
Output below
nominal setting
4-29

Advertisement

Table of Contents
loading

Table of Contents