Timer Trigger Events; Date And Time Trigger Events; Figure 3-26 Timer Trigger Event; Figure 3-27 Date And Time Trigger Event - Omega OM-DAQXL-1 Series User Manual

Multi-channel universal input touch screen data logger
Table of Contents

Advertisement

3
Standalone Operation

Timer Trigger Events

When used as a start trigger event the logging session will commence after the
data logger has been armed and the configured time period has elapsed. When
used as a stop trigger the timer sets the duration of the logging session.
1. Start Timer
2. Logging Duration
3. Repeat Trigger Events

Date and Time Trigger Events

This trigger event option allows a specific date and time to be selected to start
and/or stop a logging session. Repeat triggers are not available for this event.
1. Trigger Time
2. Trigger Date
3-23
1
3

Figure 3-26 Timer Trigger Event

The Start Timer sets the delay before logging commences in HH:MM:SS
format.
The logging during determines how long the logging session continues in
HH:MM:SS.
If repeat trigger events are enabled, the device will automatically re-arm
itself after each logging session ends.
1
2

Figure 3-27 Date and Time Trigger Event

Sets the time that the start or stop trigger occurs.
Sets the date for the start or stop trigger.
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents